CDC-585/CDC-506/CDC-685/CDC-906
CDC-585/CDC-506
CDC-685/CDC-906
■
ERROR MESSAGE
ERROR
MESSAGE
E — X 0
E — X 1
E — 7 1
E — 7 2
E — 7 3
E — X 4
E — X 5
E — X 6
E — X 7
E — X 8
E — X 9
E — X A
E r r
●
Error Messages List
DESCRIPTION
Data cannot be read after finishing search.
Data cannot be read during PLAY (x = 0), PAUSE (x = 3) or SCAN (x = 2).
At the start, tracking servo is not effective.
At the start, spindle servo PLL is not effective.
At the start, data can not read.
Close switch does not work with tray closed.
Open switch does not work with tray opened.
Table does not turn.
Traverse (Feed) inner circumference switch does not work.
Recovery action fails after focus drop.
Clamp down switch does not work.
Clamp up switch does not work.
MN35511 does not give response of SENSE, with resetting by the unit’s
microcomputer.
* Meaning of each state (“X”) :
(X = 0)PLAY
(X = 2)SCAN
(X = 3)PAUSE
(X = 4)PEAK SEARCH
(X = 5)SEARCH
(X = 6)DISC SCAN
(X = 7)START
(X = 8)STOP
(X = 9)DISC SEARCH
(X = –)EJECT
(X = C) ........... NO DISC
1) Error Code Troubleshooting
Error codes
X0 , X1 , 73 .....
Data cannot be read.
Error code
X6 ........................
Poor table rotation.
TRACKING servo
defective.
FEED servo
defective.
Check by using
another disc.
YES
NO
Outermost
(on mirror
surface)
Pick-up defective, Spindle system
defective. (Motor fails to run, etc.)
Is disc dirty or
scratched?
................ Poor tray loading
operation.
Motor defective.
Control IC (IC400) defective.
Microcomputer defective.
Does tray
operate when
OPEN/CLOSE key is
pressed?
YES
NO
SW401 detection poor.
Microcomputer defective.
DISC
SKIP
NO
YES
Does tray rotate in
TEST mode?
Tray sensor defective.
Microcomputer defective.
Motor defective.
Drive circuit defective.
Microcomputer defective.
Error code
X7 ..........
FEED operation defective.
(Limit switch fails)
FEED servo defective.
Microcomputer defective.
YES
NO
Feed limit switch
defective.
Microcomputer
defective.
Y
...Outward
T
...Inward
Is forced feed
operation available
in TEST
mode?
When stopped by any cause, press “STOP” of the remote control while pressing and holding the “STOP” on the
panel key. The operation mode turns to the mode allowing the display of messages.
The unit hold the latest error message in EEPROM. So even if stopped with no error, the unit can display the
latest error massage with same operation. (Except for CDC-585/CDC-506, which have no EEPROM. )