Trigger Output1, Trigger Output2
Sets the TRIGGER OUT 1–2 jacks to function in sync with the power status of each zone
or input switching.
Specifies the condition for the TRIGGER OUT jack to function.
Settings
Source
Specifies the output level of the electronic signal transmitted with each input,
switching when “Trigger Mode” is set to “Source”.
Choices
AV 1–7, V-AUX, AUDIO 1–3, PHONO, TUNER, (network sources), Bluetooth, USB
Settings
Manual
Switches the output level for electronic signal transmission manually when “Trigger
Mode” is set to “Manual”. This setting can also be used to confirm proper function
of the external device connected via the TRIGGER OUT jack.
Choices
Specifies the zone with which the TRIGGER OUT jack functions are synchronized.
Settings
■
Memory Guard
Prevents accidental changes to the settings.
Settings
• When “Memory Guard” is set to “On”, the lock icon (
o
) is displayed on the menu screen.
Trigger Mode
Power
The TRIGGER OUT jack functions in sync with the power status of the
zone specified with “Target Zone”.
Source
The TRIGGER OUT jack functions in sync with the input switching in
the zone specified with “Target Zone”.
An electronic signal is transmitted according to the setting made in
“Source.”
Manual
Select this to manually switch the output level for electronic signal
transmission with “Manual”.
Low
Stops the electronic signal transmission when you switch to the input
source specified in this option.
High
Transmits the electronic signal when you switch to the input source
specified in this option.
Low
Stops the electronic signal transmission.
High
Transmits the electronic signal.
Target Zone
Main
When “Trigger Mode” is set to “Power”, electronic signal transmission
is synchronized with the power status of the main zone.
When “Trigger Mode” is set to “Source”, electronic signal transmission
is synchronized with the input switching in the main zone.
Zone2
When “Trigger Mode” is set to “Power”, electronic signal transmission
is synchronized with the power status of Zone2.
When “Trigger Mode” is set to “Source”, electronic signal transmission
is synchronized with the input switching in Zone2.
All
When “Trigger Mode” is set to “Power”, electronic signal transmission
is synchronized with the power status of the main zone or Zone2.
When “Trigger Mode” is set to “Source”, electronic signal transmission
is synchronized with the input switching in the main zone or Zone2.
Off
Does not protect the settings.
On
Protects the settings until “Off” is selected.