ELEC
SIGNALING SYSTEM
8-32
1. Indicator bulb
• Remove the indicator bulb
• Connect the pocket tester (
Ω
x 1) to the bulb
(+) probe of tester
Terminal
(-) probe of tester
Terminal
• Check whether the continuity is correct in the head-
light bulb
NO CONTINUITY
Replace the indicator bulb.
CONTINUITY OK
2. Bulb holder bush of the indicator
• Place the bulb in the holder
• Disconnect the indicator wires (chocolate and black)
or (dark green and black).
• Connect the pocket tester (
Ω
x 1) to the indicator
cables
To check the right indicator:
(+) probe of tester
Dark green cable
(-) probe of tester
Black cable
To check the left-hand indicator:
(+) probe of tester
Chocolate cable
(-) probe of tester
Black cable
CHECKING AND TESTING THE SIGNALING SYSTEM
1. The indicators do not flash
NO CONTINUITY
Check/replace the indicator.
Summary of Contents for 2003 TZR50
Page 1: ...SERVICE MANUAL TZR50 X POWER 03 5WX AE1 03 ...
Page 7: ...GEN INFO 1 ...
Page 17: ......
Page 18: ...SPEC 2 ...
Page 38: ......
Page 39: ...INSP ADJ 3 ...
Page 78: ...ENG 4 ...
Page 122: ......
Page 123: ...COOL 5 ...
Page 136: ...CARB 6 ...
Page 144: ......
Page 145: ...CHAS 7 ...
Page 197: ......
Page 198: ...ELEC 8 ...
Page 200: ......
Page 201: ...ELEC ELECTRICAL DIAGRAM 8 2 ELECTRICAL DIAGRAM ...
Page 211: ...ELEC CHARGING SYSTEM 8 12 CHARGING SYSTEM CIRCUIT DIAGRAM ...
Page 216: ......
Page 217: ...ELEC LIGHTING SYSTEM 8 18 LIGHTING SYSTEM CIRCUIT DIAGRAM ...
Page 227: ...ELEC SIGNALING SYSTEM 8 28 SIGNALING SYSTEM CIRCUIT DIAGRAM ...
Page 244: ......
Page 245: ...ELEC COOLING SYSTEM 8 46 COOLING SYSTEM CIRCUIT DIAGRAM ...
Page 250: ......