Using Bulk Dump
195
02R96 Version 2—Owner’s Manual
Using Bulk Dump
02R96 data can be stored to an external MIDI device, such as a MIDI data filer, by using
MIDI Bulk Dump.
1
Use the DISPLAY ACCESS [MIDI] button to locate the Bulk Dump page.
2
To transmit data, use the CATEGORY parameters to select the type of data
you want to transmit, select the TRANSMIT button, and then press [ENTER].
The INTERVAL parameter sets the interval between data packets during transmission.
The CATEGORY parameters can be set as follows:
ALL:
All data.
SCENE MEM:
ALL Scenes, individual Scenes, or current (i.e., the Edit buffer).
AUTOMIX:
ALL Automixes, individual Automixes, or the current Automix.
LIBRARY:
The following libraries: EQ, Gate, Comp, Channel, Effects, Bus to Stereo, Input
Patch, Output Patch, Surround Monitor. For each library you can specify ALL user memo-
ries, individual user memories, and for the Bus to Stereo, Input Patch, Output Patch, Sur-
round Monitor libraries you can also specify the current settings.
BANK:
User Defined Remote Layer banks (RMT UDEF), User Defined Plug-Ins banks
(PLUG UDEF), User Defined Keys banks (KEYS UDEF), or the USER ASSIGNABLE
LAYER banks (USR LAYER). For each item you can specify ALL or individual banks.
SETUP MEM:
02R96 setup data (i.e., system settings).
PGM TABLE:
Scene to MIDI Program Change table. See “Assigning Scenes to Program
CTL TABLE:
Parameter to MIDI Control Change table. See “Assigning Parameters to Con-
PLUG-IN:
The settings of any installed Y56K cards. You can specify ALL Slots or Slot 3 or 4.
3
You can also transmit 02R96 data via a MIDI cable. To receive data, use the
CATEGORY parameters to select the type of data you want to receive, select
the REQUEST button, then press [ENTER].