Selecting the Timecode Source & Frame Rate
The timecode source and frame rate for Automix can be set as follows.
1
Use the DISPLAY ACCESS [SETUP] button to select the Time Reference page.
2
Use the cursor buttons to select the parameters, and use the Parameter
wheel, INC/DEC buttons, and [ENTER] button to set them.
TIME REFERENCE:
The following timecode sources can be selected.
For the USB and SERIAL sources, you must specify a port from 1–8.
FRAMES:
The frame rate can be set to: 30, 30D, 29.97, 29.97D, 25, or 24. An Automix will
playback correctly even if the frame rate is different to that which was used when the Auto-
mix was originally recorded.
The MIDI CLOCK source supports Song position Pointers, F8 TIMING CLOCK (timing
info), FA START (starts Automix from beginning), FB CONTINUE (starts Automix from
current position), and FC STOP (stops Automix).
Source
Description
INTERNAL
Internally generated timecode
SMPTE
SMPTE timecode received via the SMPTE TIME CODE INPUT
MIDI CLOCK
MIDI Clock received via the MIDI IN port
MTC
MTC received via the MTC TIME CODE INPUT
USB
MTC received via the USB TO HOST port
SERIAL
MTC received via the SERIAL TO HOST port
SLOT1
MTC received via Slot #1 (for use with an optional mLAN I/O Card installed in Slot #1)
MIDI
MTC received via the MIDI IN port