204
Specifications
Digital Recording Console 02R User’s Guide
Error Messages
Follow the corrective actions described below when the error messages are shown on the display:
Error Message
Corrective Action
2TR-D1 No Input!
Correct digital signal is not input to 2TR-D1.
(C-R monitoring is not available.)
2TR-D2 Cascade Disabled
2TR-D2 cannot be routed to STEREO BUS.
(Incorrect word clock setting)
2TR-D2 No Input!
Correct digital signal is not input to 2TR-D2.
(C-R monitoring is not available.)
2TR-D3 No Input!
Correct digital signal is not input to 2TR-D3.
(C-R monitoring is not available.)
Automix Aborted!
Automix data was aborted.
(You can undo the operation.)
Automix Disabled!
Time code was input, but automix is disabled.
Automix REC Ready!
Ready for recording automix.
Automix Recording!
Recording automix now.
Automix Running!
Automix is now running.
Automix Updated!
Automix has been updated.
(You can undo the operation.)
Byte Count Error!
Byte count for the received bulk data is not correct.
Can't assign 2TR-D1!
2TR-D1 cannot be routed to line 17/18. (The signal at 2TR-D1 is not
syncing with the 02R, or 2TR-D1 has been selected in the C-R monitor
section.)
Can't assign 2TR-D2!
2TR-D2 cannot be routed to line 19/20. (The signal at 2TR-D2 is not
syncing with the 02R, or 2TR-D2 has been selected in the C-R monitor
section.)
Can't select SLOT3!
SLOT3 cannot be selected for digital input.
(The I/O card is not in SLOT3.)
Can't select SLOT4!
SLOT4 cannot be selected for digital input.
(The I/O card is not in SLOT4.)
Can't select WORD CLOCK!
Not available as a word clock source.
Cannot Copy Title!
You cannot copy the title from the memory that has no data.
Cannot Paste Title!
You cannot paste the title to the memory that has no data.
Check Sum Error!
Check sum of the received bulk data is not correct.
Code Mismatch!
Product code for the received bulk data is not correct.
DIGITAL I/O Error!
Incoming signal from SLOT DIO is not syncing with the 02R. The syn-
chronization system has not been configured successfully. Or, if the
sync system has been configured, this message may still appear if the
clock sent from the MTR is unstable until the digital MTR enters CHASE
status. You can select whether this message will be shown or not. (see
“Preferences” on page 162 of the User’s Guide)
Duplicate Grouping!
You cannot duplicate the group.
Summary of Contents for 02R
Page 1: ...DIGITAL RECORDING CONSOLE E...
Page 7: ...DIGITAL RECORDING CONSOLE User s Guide User s Guide...
Page 21: ...12 Introduction to the 02R Digital Recording Console 02R Getting Started Guide...
Page 27: ...18 Getting Started Digital Recording Console 02R Getting Started Guide...
Page 49: ...40 Introductory Recording Tutorial Digital Recording Console 02R Getting Started Guide...
Page 75: ...66 Secondary Recording Tutorial Digital Recording Console 02R Getting Started Guide...
Page 103: ...94 Index Digital Recording Console 02R Getting Started Guide...
Page 104: ...DIGITAL RECORDING CONSOLE Getting Started Guide Getting Started Guide...
Page 106: ...ii Sections Digital Recording Console 02R User s Guide...
Page 126: ...16 Controls and Connections Digital Recording Console 02R User s Guide...
Page 192: ...82 Dynamics Digital Recording Console 02R User s Guide...
Page 222: ...112 Internal Effects Digital Recording Console 02R User s Guide...
Page 232: ...122 Scene Memories Digital Recording Console 02R User s Guide...
Page 262: ...152 Groups and Pairs Digital Recording Console 02R User s Guide...
Page 335: ...224 Specifications Digital Recording Console 02R User s Guide...
Page 343: ...232 Glossary Digital Recording Console 02R User s Guide...