56
O1X
1.3 Initialization
After upgrading the version of the program or installing a
new ROM, the values of the backup ROM must be initialized.
UTILITY
REMOTE
SCENE
STANDBY/ON
PAN
KNOB-8
KNOB-7
■
INSPECTIONS
1.2 Measuring Instruments, jigs
Following measuring instrument, jigs, etc. are required for
testing the main unit.
Measuring instruments:
• Low frequency oscillator ( output waveform distortion:
0.01% or less, usable for both balanced and unbalanced
cases)
• DC volt meter
• Distortion meter (usable for both balanced and
unbalanced cases, 12.7kHz LPF, 20kHz LPF)
• Function generator
• Digital audio analyzer System Two CASCADE or its
equivalent
• Level meter (12.7kHz LPF, input impedance: 1M
Ω
or
more)
• Oscilloscope (input impedance: 1M
Ω
or more)
• Ammeter (impedance: as low as 1
Ω
or less, measuring
range: as wide as to cover 70mA to 1.1A fully)
Jigs:
• MIDI cable
• Coaxiable digital cable (75
Ω
)
• Foot switch (FC5, etc.)
Others:
• Reproduction equipment with an analog output
(balanced/unbalanced)
• Keyboard amplifier (KS15 or equivalent)
1. Preparations
1.1 Conditions
(1) Set switches and VR knobs as follows unless otherwise
specified.
1) PHANTOM SW: OFF
2) INPUT GAIN VR: LINE
3) MONITOR/PHONES VR: MIN
4) CH FADER: NOMINAL (0dB)
5) STEREO FADER: NOMINL (0dB)
(2) Set the word clock to internal 48kH.
(3) Select only the INPUT CH to be tested.
(4) Set the PAN to the center position.
(5) Set the oscillator output impedance to 150
Ω
.
(6) Set the load resistance of the analog input as follows.
1) MONITOR OUT: 10k
Ω
2) STEREO/AUX OUT: 10k
Ω
3) PHONES: 39
Ω
+ 39
Ω
(7) Use the following unit for the analog input/output level.
0dBu = 0.775Vrms
0dBV = 1Vrms = +2.2dBu
(1) When clearing all the backup data
While pressing the "REMOTE", "UTILITY" and "PAN"
buttons, turn on the power (keep pressing until the following
message appears on the screen).
Do
you
want
initialize
backup
data?
YES
NO
Pressing the encoder switch [KNOB-7] corresponding to
YES will execute initialization.
Z
CAUTION
*
When you restore the factory default settings, all the settings
for the all the Libraries and Utility will be overwritten with
the factory defaults. Make sure you are not overwriting any
important data. You should backup any important data to
your computer beforehand by using Studio Manager. (For
more details on using Studio Manager, see the Studio
Manager PDF manual.)
*
Never attempt to turn off the power while data is being written
to Flash ROM (while an “Initializing backup data, please keep
power on...” message is shown). Turning the power off in
this state results in loss of all user data and may cause the
system to freeze (due to corruption of data in the Flash ROM).
Summary of Contents for 01x
Page 7: ...7 O1X Units mm 単位 DIMENSIONS 寸法図 453 39 1 116 ...
Page 38: ...38 O1X B B AN Circuit Board 2NA WA21730 2 1 ...
Page 39: ...39 O1X B B Pattern side 2NA WA21730 2 1 パターン側 ...
Page 40: ...40 O1X DM Circuit Board 2NA WA21700 1 2 to MLN2 CN6 to AN CN202 to AN CN101 C C ...
Page 42: ...42 O1X D D DM Circuit Board 2NA WA21700 2 2 ...
Page 43: ...43 O1X D D Pattern side 2NA WA21700 2 2 パターン側 ...
Page 47: ...47 O1X 2NA WB95270 MF Circuit Board Pattern side パターン側 ...
Page 49: ...49 O1X F F F F 2NA WC02570 RE Circuit Board Pattern side パターン側 ...
Page 51: ...51 O1X Pattern side パターン側 2NA WA97910 1 MLN2 Circuit Board ...