Yale UniTrol UNI-50BC Series Installation Instructions Download Page 1

Installation Instructions

80-9350-2514-010 (07-09)

Non Hold Open (UL Listed)
Hold Open (H) (Not UL Listed)

An incorrectly installed or improperly
adjusted door closer can cause
property damage or personal injury.
These instructions should be followed
to avoid the possibility of misapplication
or misadjustment.

CAUTION

CAUTION

Page 1

Components:

UniTrol Door Controls

®

UNI-50BC Series
UNI-51(BF) Series

Sized Closers

Multi-Sized Closers

Sized

(Sizes 2, 3, 4, 5, 6)

UNI-52BC(H)
UNI-53BC(H)
UNI-54BC(H)
UNI-55BC(H)
UNI-56BC(H)

Multi-Sized

(Sizes 3 thru 6)

(Sizes 1 thru 4)

UNI-51BF(H)

UNI-51(H)

“DL” suffix (Delayed Action) is an optional feature. A separate instruction

.

will be

packed with these instructions, showing valve locations and adjustment procedures

Power Adjustment Screw
(1/8 Hex Drive)
51, 51BF Only

"BC" Valve

Pinion Cap

Closer
Size
Stamp

"L"Valve

"S"Valve

4

Soffit Plate

For special applications a separate door and frame preparation template is packed with these instructions

Use this instruction sheet for installation sequence and closer adjustments only

•  It is recommended that the door on which the door closer will be installed be hung on ball bearing hinges. Door must swing freely

•  Door and Frame must be properly reinforced, or use of special fasteners employed, to prevent the mounting screws from pulling out.

•  All dimensions are given in inches with corresponding metric dimensions (mm) in parenthesis.

NOTE:

Standard Frame

Installation

1-7/8 to 4-5/8

Frame Reveals

(Uses 6190 Bracket).

Bracket illustration page 4.

See Page 2

Deep Frame

Installation

Frame Reveals Over 4-5/8

(Uses 6191 Clamp Kit).

Bracket illustration page 4.

See Page 3

Flush Transom

Installation

Flush Partitions

(Uses 589L Bracket).

Bracket illustration page 4.

See Page 4

Left Hand Door - LH

Right Hand Reverse - RHR

Right Hand Door - RH
Left Hand Reverse - LHR

Hinge Edge of Door

Hinge Edge of Door

Right Hand Door - RH
Left Hand Reverse - LHR

Left Hand Door - LH

Right Hand Reverse - RHR

Arm Identification

Arm Stamping

Door Width

Main Arm

Non Hold Open

Hold Open

28” - 32”

(0.70 - 0.80m)

33” - 41”

(0.85 - 1.00m)

42” - 48”

(1.05 - 1.20m)

9-1/2”

(241mm)

11”

(279mm)

12-1/2”

(318mm)

6100-11

6100-13

6100-14

6100-1

6100-3

6100-4

Main Arm

Hold-Open Option

UniTrol Parallel

Arm Assembly

Optional

Cover

50P

Hinge Edge of Door

Hinge Edge of Door

Right Hand Door - RH
Left Hand Reverse - LHR

Left Hand Door - LH

Right Hand Reverse - RHR

Models:

Summary of Contents for UniTrol UNI-50BC Series

Page 1: ... door on which the door closer will be installed be hung on ball bearing hinges Door must swing freely Door and Frame must be properly reinforced or use of special fasteners employed to prevent the mounting screws from pulling out All dimensions are given in inches with corresponding metric dimensions mm in parenthesis NOTE Standard Frame Installation 1 7 8 to 4 5 8 Frame Reveals Uses 6190 Bracket...

Page 2: ...298 286 Reveal Reveal Reveal Reveal Door template is typical for all installations Frame template must be selected according to frame reveal Frame Template at right Frame Reveals 1 7 8 48 to 4 5 8 117 Uses 6190 Bracket Bracket Illustration Page 4 Frame Template Page 2 Frame Reveals Over 4 5 8 117 Uses 6191 Clamp Kit Bracket Illustration Page 4 Frame Template Page 3 Frame Reveals 0 to 1 8 0 to 3 Fl...

Page 3: ...L valves toward the lock edge of the door If using optional cover see Cover instructions at bottom of Page 4 Typical Installation Pinion Flat Mount Arm to Frame Fasten soffit plate or 589L angle bracket if flush partition to frame Mount 6190 bracket or 6191 clamps to reinforce soffit plate Install Arm on Pinion Shaft Screw pinion cap onto the pinion shaft by hand or with a Phillips screw driver DO...

Page 4: ...guidelines L Valve S Valve 1 8 Hex Key Slow Fast 1 8 Hex Key Increase Decrease BC Valve 4 Closing Power Control Figure 3 1 8 Hex Key Increase Decrease Adjust as required Product is shipped at mid range power setting Bracket Illustrations Door Holder Option Figure 4 Power Adjustment Chart DOOR INT EXT PARALLEL ARM INSTALLATION MAXIMUM DOOR SIZE 34 0 85 m 36 0 9 m 40 1 m 44 1 1 m 48 1 2 m 18 360 TUR...