TO Flame Sensing Evaluation Kit (Analog) USEQFCK4000000

 

The above information is believed to be correct but does not purport to be all inclusive and must be used only as a guide.

  

 

© KEMET 

Electronics Corporation • KEMET Tower • One East Broward Boulevard 

Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com           

1

 

 

 

 

 

 

 

TO Pyroelectric Infrared 

Flame Sensing Evaluation Kit 

USEQFCK4000000

 

 

 

 
 
 

User Guide 

Rev. 2.2 

 

MAR 2022 

 

 

Summary of Contents for KEMET USEQFCK4000000

Page 1: ...t but does not purport to be all inclusive and must be used only as a guide KEMET Electronics Corporation KEMET Tower One East Broward Boulevard Fort Lauderdale FL 33301 USA 954 766 2800 www kemet com...

Page 2: ...INTRODUCTION 3 2 GETTING STARTED 3 2 1 Kit Contents 3 2 2 Minimum System Requirements 3 3 INSTALLATION 4 3 1 Installing the KEMET Flame Sensing Evaluation Tool Software 4 3 2 Connecting the TO Flame...

Page 3: ...sed algorithm and to capture measured data to a PC The kit is based on the Silicon Labs C8051F350 microcontroller with a high precision A D converter and programmable gain amplifier It is capable of s...

Page 4: ...while to install but the software requires it 3 2 Connecting the TO Flame Sensing Evaluation Kit Connect the power supply provided to the KEMET Flame Detection Demonstrator Kit Then connect the USB ca...

Page 5: ...com 5 4 1 Starting the Software To start the software select the following from the windows start button in your task bar This will open up the KEMET sensor data capture main screen as shown below Fi...

Page 6: ...re 4 Flame Detection Demonstrator Kit Connection This will open up a further dialog box asking you to select on which com port the data capture board is using as shown in Figure Figure 5 Com Port Sele...

Page 7: ...how the Flame Detection Demonstrator Kit firmware version Sensor signal will be visible on the signal viewers on the right If the program fails to make a connection to the data capture board an error...

Page 8: ...channel Gain of 1 means no additional amplification is applied to the sensor signal thus x1 The remaining settings of X give multiples of the signal levels obtained at gain of 1 For example gain selec...

Page 9: ...cy domain representation of the signal useful for looking at dominant frequencies in signals relative magnitude for example comparison of flame flicker frequency and human motion frequency o 10 Hz Sig...

Page 10: ...tion However detection time is increased to around 15 seconds with the highest setting 10 Hz Response This is the final result from the preprocessing for each channel The relative levels from the chan...

Page 11: ...n front of the sensors Expected outcome a Signal viewer for Ch1 flame filter i generally a higher response is shown on Ch1 for flame test at the moment of starting the flame than on Ch2 for hand wavin...