Menu Selection Details

FTM-3100R/E Advance Manual

28  RPT ARS

Function:

 Activates/Deactivates the Automatic Repeater Shift feature..

Available Values:

 ON / OFF

Default:

 ON

29  RPT FREQ

Function:

 Sets the magnitude of the Repeater Shift.

Available Values:

 0.00 - 150.00 MHz

Default:

 0.60 MHz

30  RPT SFT

Function:

 Sets the Repeater Shift direction.

Available Values:

 - RPT / + RPT / SIMPLEX

Default:

 SIMPLEX

31  SCAN RSM

Function:

 Selects the Scan Resume mode.

Available Values:

 BUSY / HOLD / 2.0 SEC - 10.0 SEC (0.5 SEC step)

Default:

 5.0 SEC

BUSY: 

The scanner will hold until the signal disappears, then will resume 
when the carrier drops.

HOLD: 

The scanner will stop when a signal is received, and will not restart.

2.0 SEC - 10.0 SEC: The scanner will hold for the selected resume time, then resume 

scanning, whether or not the other station is still transmitting.

32  SCAN SKP

Function:

 Selects the Memory Scan mode.

Available Values:

 SKIP/SELECT/OFF

Default:

 OFF

SKIP: 

The scanner will “skip” the flagged channels during scanning.

SELECT:  The scanner will only scan channels that are flagged (Preferential Scan List).
OFF: 

All memory channels will be scanned (the “flag” will be ignored).

33  SQL EXP

Function:

 Enables/Disables the split CTCSS/DCS coding.

Available Values:

 ON / OFF

Default:

 OFF

When this Set Mode Item is set to “ON”, the following additional parameters are available 
after the “PAGER” parameter when configuring Set Mode Item “34 SQL TYPE”:
D CODE:  DCS Encode only.
T DCS:  Encodes a CTCSS tone and Decodes a DCS code.
D TONE:  Encodes a DCS code and Decodes a CTCSS tone.

Summary of Contents for FTM-3100E

Page 1: ...FTM 3100R E Advance Manual VOL DIAL SQL D W M W SETUP REV TXPO V M MH z VHF FM TRANSCEIVER...

Page 2: ...de 11 Transmitting the registered DTMF code 12 Setting DTMF Autodialer sending Speed 12 Setting DTMF Autodialer TX delay time 13 Memory Operation 14 Split Memory 14 Moving Memory Data to the VFO 14 Me...

Page 3: ...r one second to save the new setting and exit to normal operation VOL DIAL D W M W SETUP REV SQL TXPO V M MHz RF Squelch A special RF Squelch feature is provided on this radio which allows setting the...

Page 4: ...eys the choices include SQL OFF Open the Squelch to allow un muted reception HOME Recall the home channel WX CH Switches operation to the Weather channels bank CD SRCH Engages the Tone or DCS Search S...

Page 5: ...ey then rotate the DIAL knob to select ON Default OFF VOL DIAL D W M W SETUP REV SQL TXPO V M MHz 4 Press the MHz SETUP key momentarily then rotate the DIAL knob to select SQL TYPE 34 5 Press the MHz...

Page 6: ...e correct tone scanning will halt on that tone and audio will be allowed to pass 4 Press the assigned Programmable key of the Microphone to lock in that tone and exit to normal operation Note You may...

Page 7: ...the correct code scanning will halt on that code and audio will be allowed to pass 4 Press the assigned Programmable key of the Microphone to lock in that tone and exit to normal operation Note You ma...

Page 8: ...transmitted automatically On the paged radio the squelch will close automatically after the incoming page ends Storing CTCSS Tone Pairs for EPCS Operation 1 Press and hold in the MHz SETUP key for one...

Page 9: ...L TXPO V M MHz 3 Press the MHz SETUP key and then rotate the DIAL knob to select PAGER 4 Press and hold in the MHz SETUP key for one second to save the new setting and exit to normal operation 5 To di...

Page 10: ...ed in the following table 1209 Hz 1336 Hz 1477 Hz 1633 Hz 697 Hz 1 2 3 A 770 Hz 4 5 6 B 852 Hz 7 8 9 C 941 Hz 0 D Transmitting a DTMF code manually You can generate DTMF tones during transmission manu...

Page 11: ...u can also use the keypad on the microphone to input the DTMF code 5 When you have selected the correct digit press the V M MW key momentarily Now rotate the DIAL knob to select the second of 16 avail...

Page 12: ...ss the microphone numeric key 0 through 9 corresponding to the DTMF memory string you wish to send Once the string begins you may release the PTT switch as the transmitter will be held on the air unti...

Page 13: ...in the MHz SETUP key for one second to enter the Set mode 2 Rotate the DIAL knob to select DT DELAY 11 3 Press the MHz SETUP key momentarily and then rotate the DIAL knob to select the desired delay...

Page 14: ...nnel can easily be moved to the VFO 1 Select the memory channel containing the frequency data to be moved to the VFO 2 Press and hold in the V M MW key for one second and then press the MHz SETUP key...

Page 15: ...L key to back space the cursor then re enter the correct letter number or symbol 7 Repeat steps 5 through 6 to program the re maining letters numbers or symbols of the desired label A total of 8 chara...

Page 16: ...nal disappears and then restart scan ning 2 seconds after the signal disappears BUSY 3 Stop scanning and receive that frequency HOLD 1 Press and hold in the MHz SETUP key for one second to enter the S...

Page 17: ...one second then rotate the DIAL knob to select SCAN SKP 32 4 Press the MHz SETUP key then rotate the DIAL knob to select SKIP The current Memory Channel will now be ignored during scanning VOL DIAL D...

Page 18: ...nel number appear on the right side of the display 2 Rotate the DIAL knob to select the Memory Channel that you wish to add to the prefer ential Scan List VOL DIAL D W M W SETUP REV V M MHz SQL TXPO 3...

Page 19: ...VOL DIAL D W M W SETUP REV V M MHz SQL TXPO Note While operating in the Memory Storage mode the keypad of the MH 48A6JA Microphone may be used to enter the memory channel number directly To do this en...

Page 20: ...scanning stops press the key on the MH 48A6JA Microphone Band Edge Beeper The FTM 3100R E will automatically beep when the receive band edge is encountered during scanning either in standard VFO scan...

Page 21: ...set the FTM 3100R E for operation on another memory channel Home channel or on a VFO frequency 6 Press and hold in the REV DW key for one second The display will remain on the VFO the selected memory...

Page 22: ...ully activated in this step 4 On the Destination radio press the MHz SETUP key WAIT will appear on the display 5 On the Source radio press the REV DW key TX will appear on the Source radio and the dat...

Page 23: ...ble Values Default 1 APO Enables Disables the Automatic Power Off feature 0 5H to 12H 0 5H step OFF OFF 2 BCLO Enables Disables the Busy Channel Lock Out feature ON OFF OFF 3 BEP KEY Enables Disables...

Page 24: ...P2 Programming the function assigned to Microphone P2 key HOME 25 PRG P3 Programming the function assigned to Microphone P3 key CD SRCH 26 PRG P4 Programming the function assigned to Microphone P4 key...

Page 25: ...W FAST 41 VER DISP Displays the transceiver software version CPU x xx DSP x xx 42 WX ALERT Enables Disables the Weather Alert fea ture ON OFF OFF 43 WX VOL Selects the audio output level of the Weathe...

Page 26: ...y is pressed or when the scanner stops KEY The beeper sounds when any key is pressed OFF Beeper is disabled 4 BEP EDGE Function Enables Disable the Band edge beeper while scanning Available Values ON...

Page 27: ...unication direction Available Values NORMAL INVERT BOTH Default NORMAL NORMAL Homeomorphic INVERT Inverted Phase BOTH Both Phase 10 DT AUTO Function Enables Disables the DTMF Autodialer feature Availa...

Page 28: ...pening Message that appears when the radio is powered ON Available Values DC MESSAGE OFF Default MESSAGE DC DC supply voltage MESSAGE Set by user See below OFF No Opening Message Here s how to program...

Page 29: ...Available Values SQL OFF HOME WX CH CD SRCH SCAN T CALL TX POWER or one of the all Set mode items except Set mode items 23 through 26 initial setting is Set mode item 15 LCD DMMR Default HOME 25 PRG P...

Page 30: ...and will not restart 2 0 SEC 10 0 SEC The scanner will hold for the selected resume time then resume scanning whether or not the other station is still transmitting 32 SCAN SKP Function Selects the M...

Page 31: ...he current temperature inside the transceiver 37 TONE FRQ Function Setting of the CTCSS Tone Frequency Available Values 50 standard CTCSS tones Default 100 0 Hz CTCSS TONE FREQUENCY Hz 67 0 69 3 71 9...

Page 32: ...Values CPU 42 WX ALERT Function Enables Disables the Weather Alert feature Available Values ON OFF Default OFF ON The weather alert will be received OFF The weather alert will not be received 43 WX VO...

Page 33: ...without the permission of YAESU MUSEN CO LTD YAESU MUSEN CO LTD Tennozu Parkside Building 2 5 8 Higashi Shinagawa Shinagawa ku Tokyo 140 0002 Japan YAESU USA 6125 Phyllis Drive Cypress CA 90630 U S A...