background image

YAESU MUSEN CO., LTD.

CAT Operation Reference Manual

101MP

101D

Summary of Contents for FTDX101MP

Page 1: ...YAESU MUSEN CO LTD CAT Operation Reference Manual 101MP 101D...

Page 2: ...intended to help you start writing programs on your own As you become more familiar with CAT operation you can customize programs for your operating needs and utilize the full operating potential of t...

Page 3: ...rt configuration select the COM port numbers that were confirmed using the procedure above If a or X is displayed for the port on the Device Manager uninstall and reinstall the virtual COM driver If a...

Page 4: ...2 Use an external antenna tuner connected to the ANT 2 connector EXT3 Use an external antenna tuner connected to the ANT 3 RX connector NOTE The RS 232C jack cannot be used while using the external an...

Page 5: ...lphabetical characters You may use either lower or upper case characters The commands available for this transceiver are listed in the PC Control Command Tables on the following pages Parameters Param...

Page 6: ...RY CHANNEL TO MAIN BAND O X X X MB MEMORY CHANNEL TO SUB BAND O X X X MC MEMORY CHANNEL O O O X MD MODE O O O O MG MIC GAIN O O O O ML MONITOR LEVEL O O O O MR MEMORY READ X O O X MS METER SW O O O O...

Page 7: ...AI command is available only when PC is connected with USB cable This parameter is set to 0 OFF automatically when the transceiver is turned OFF A I P1 Read 1 2 3 4 5 6 7 8 9 10 A I Answer 1 2 3 4 5 6...

Page 8: ...7 8 9 10 B I P1 BM SUB BAND TO MEMORY CHANNEL Set 1 2 3 4 5 6 7 8 9 10 B M Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 BP MANUAL NOTCH Set 1 2 3 4 5 6 7 8 9 10 P1 0 MAIN BAND P3 P2 0 1 SUB...

Page 9: ...049 254 1 Hz 005 79 7 Hz 014 107 2 Hz 023 146 2 Hz 032 177 3 Hz 041 206 5 Hz 006 82 5 Hz 015 110 9 Hz 024 151 4 Hz 033 179 9 Hz 042 210 7 Hz 007 85 4 Hz 016 114 8 Hz 025 156 7 Hz 034 183 5 Hz 043 218...

Page 10: ...t 1 2 3 4 5 6 7 54 55 P1 0 RTTY 1 DATA P2 0 3 3 ch 1 1 ch 4 4 ch 2 2 ch 5 5 ch P3 Message Characters up to 50 characters ASCII E M P1 P2 P3 P3 P3 P3 Read 1 2 3 4 5 6 7 54 55 E M P1 P2 Answer 1 2 3 4 5...

Page 11: ...Hz steps 2 07 HCUT SLOPE 0 6 dB oct 1 18 dB oct 1 08 FM OUT SELECT 0 MAIN 1 SUB 1 09 FM OUT LEVEL 000 100 3 10 FM MOD SOURCE 0 MIC 1 REAR 1 11 MIC GAIN 1000 MCVR 0000 0100 FIX 4 12 REAR SELECT 0 DATA...

Page 12: ...UMBER 0001 9999 4 08 CW MEMORY 1 0 TEXT 1 MESSAGE 1 09 CW MEMORY 2 0 TEXT 1 MESSAGE 1 10 CW MEMORY 3 0 TEXT 1 MESSAGE 1 11 CW MEMORY 4 0 TEXT 1 MESSAGE 1 12 CW MEMORY 5 0 TEXT 1 MESSAGE 1 13 REPEAT IN...

Page 13: ...100 P4 005 100 FTDX101D 5 200 P4 005 200 FTDX101MP 3 02 50M MAX POWER 5 100 P4 005 100 FTDX101D 5 200 P4 005 200 FTDX101MP 3 03 70M MAX POWER 5 50 P4 005 050 3 04 AM MAX POWER 5 25 P4 005 025 FTDX101...

Page 14: ...Read 1 2 3 4 5 6 7 8 9 10 F R Answer 1 2 3 4 5 6 7 8 9 10 F R P1 P2 FS FAST STEP Set 1 2 3 4 5 6 7 8 9 10 P1 0 MAIN Band FAST Key OFF 1 MAIN Band FAST Key ON 2 SUB Band FAST Key OFF 3 SUB Band FAST Ke...

Page 15: ...P1 P1 P1 P2 P2 P2 P2 P2 11 12 13 14 15 16 17 18 19 20 P2 P2 P2 P2 P3 P3 P3 P3 P3 P4 21 22 23 24 25 26 27 28 29 30 P5 P6 P7 P8 P9 P9 P10 IS IF SHIFT Set 1 2 3 4 5 6 7 8 9 10 P1 0 MAIN Band RX 1 SUB Ba...

Page 16: ...Stop 1 DVS CH 1 Recording Start Stop 2 DVS CH 2 Recording Start Stop 3 DVS CH 3 Recording Start Stop 4 DVS CH 4 Recording Start Stop 5 DVS CH 5 Recording Start Stop L M P1 P2 Read 1 2 3 4 5 6 7 8 9 1...

Page 17: ...MP 2 ID 3 SWR M S P1 P2 Read 1 2 3 4 5 6 7 8 9 10 M S Answer 1 2 3 4 5 6 7 8 9 10 M S P1 P2 MT MEMORY CHANNEL WRITE TAG Set 1 2 3 4 5 6 7 8 9 10 P0 1 001 099 Memory Channel P1L P9U PMS 5xx 5MHz BAND E...

Page 18: ...10 Answer 1 2 3 4 5 6 7 8 9 10 MX MOX SET Set 1 2 3 4 5 6 7 8 9 10 P1 0 MOX OFF 1 MOX ON M X P1 Read 1 2 3 4 5 6 7 8 9 10 M X Answer 1 2 3 4 5 6 7 8 9 10 M X P1 NA NARROW Set 1 2 3 4 5 6 7 8 9 10 P1 0...

Page 19: ...2 Minus Shift This command can be activated only with an FM mode O S P1 P2 Read 1 2 3 4 5 6 7 8 9 10 O S P1 Answer 1 2 3 4 5 6 7 8 9 10 O S P1 P2 PA PRE AMP IPO Set 1 2 3 4 5 6 7 8 9 10 P1 0 MAIN Band...

Page 20: ...1 2 3 4 5 6 7 8 9 10 Q R Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 QS QUICK SPLIT Set 1 2 3 4 5 6 7 8 9 10 Q S Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 RA RF ATTENUATOR Set 1...

Page 21: ...ide Meter 0 255 P3 Right side Meter 0 255 P1 1 S MAIN Band 2 S SUB Band 3 COMP 4 ALC 5 PO 6 SWR 7 IDD 8 VDD 9 TEMP P2 0 255 P3 0 Read 1 2 3 4 5 6 7 8 9 10 R M P1 Answer 1 2 3 4 5 6 7 8 9 10 R M P1 P2...

Page 22: ...t Default Default Default Default 01 300 Hz 50 Hz 50 Hz 50 Hz 02 400 Hz 100 Hz 100 Hz 100 Hz 03 600 Hz 150 Hz 150 Hz 150 Hz 04 850 Hz 200 Hz 200 Hz 200 Hz 05 1100 Hz 250 Hz 250 Hz 250 Hz 06 1200 Hz 30...

Page 23: ...CILLOSCOPE P1 0 Fixed P3 0 AF FFT ATT 0dB 1 AF FFT ATT 10dB 2 AF FFT ATT 20dB P4 0 OSC Level ATT 0dB 1 OSC Level ATT 10dB 2 OSC Level ATT 20dB P5 0 OSC Time 1msec 1 OSC Time 3msec 2 OSC Time 10msec 3...

Page 24: ...8 9 10 V D P1 P1 P1 P1 VG VOX GAIN Set 1 2 3 4 5 6 7 8 9 10 P1 000 100 V G P1 P1 P1 Read 1 2 3 4 5 6 7 8 9 10 V G Answer 1 2 3 4 5 6 7 8 9 10 V G P1 P1 P1 VM MAIN BAND TO MEMORY CHANNEL Set 1 2 3 4 5...

Page 25: ...4 5 6 7 8 9 10 P1 0 TX CLAR OFF 1 TX CLAR ON X T P1 Read 1 2 3 4 5 6 7 8 9 10 X T Answer 1 2 3 4 5 6 7 8 9 10 X T P1 ZI ZERO IN Set 1 2 3 4 5 6 7 8 9 10 CW AUTO ZERO IN Function P1 0 MAIN Band 1 SUB B...

Page 26: ...roduced without the permission of YAESU MUSEN CO LTD YAESU MUSEN CO LTD Tennozu Parkside Building 2 5 8 Higashi Shinagawa Shinagawa ku Tokyo 140 0002 Japan YAESU USA 6125 Phyllis Drive Cypress CA 9063...