FT-60R O
PERATING
M
ANUAL
73
Set Mode Item 21
[
I NET
]
Function
: Selects the Internet Link Connection mode.
Available Values
: INT.OFF/INT.COD/INT.MEM
Default
: INT.OFF
INT.OFF: Disables the Internet Link Connection mode.
INT.COD: Sets up the Internet Link Connection mode for WIRES™ access.
INT.MEM: Sets up the Internet Link Connection mode for other (DTMF string) Internet
Link System access.
Set Mode Item 22
[
INT CD
]
Function
: Selects the Access Number (DTMF digit) for WIRES
TM
operation.
Available Values
: CODE 0 - CODE 9
Default
: CODE 1
Set Mode Item 23
[
INT MR
]
Function
: Selects the memory register for an Access Number (DTMF code) for non-
WIRES™ Internet Link System access.
Available Values
: d1 - d9
Default
: d1
Set Mode Item 24
[
LAMP
]
Function
: Selects the LCD/Keypad Lamp mode.
Available Values
: KEY/5SEC/TOGGLE
Default
: KEY
KEY:
Illuminates the Keypad/LCD for five seconds when you rotate the
DIAL
knob
or press any key or switch (except the
PTT
switch).
5SEC:
Illuminates the Keypad/LCD for five seconds when you press the
LAMP
switch
momentarily.
TOGGLE: Toggles the Keypad/LCD lamp on and off when you press the
LAMP
switch
repeatedly.
Set Mode Item 25
[
LOCK
]
Function
: Selects the Control Locking lockout combination.
Available Values
: LK KEY/LKDIAL/LK K+D/LK PTT/LK P+K/LK P+D/LK ALL
Default
: LK KEY
Note
: “K” = “Key;” “D” = “Dial;” and “P” = “PTT.”
S
ET
(
M
ENU
)
M
ODE