Frequency Navigation
1
)
Tuning Dial
Rotating the
DIAL
knob allows tuning in the pre-programmed steps. Clockwise rotation
of the
DIAL
knob causes the
FT-2980R/E
to be tuned toward a higher frequency, while
counter-clockwise rotation will lower the operating frequency.
Press the [
MHz
(
SET
)] key momentarily, then rotate the
DIAL
knob, to change the
frequency steps to 1 MHz per step. This feature is extremely useful for making rapid
frequency excursions over the wide tuning range of the
FT-2980R/E
. Instead of pressing
the [
MHz
(
SET
)] button, you may also press the [
A
] key on the Microphone’s keypad to
engage tuning in 1 MHz steps.
2
)
Direct Keypad Frequency Entry
The keypad of the
MH-48
A6J
DTMF Microphone may be used for direct entry of the
operating frequency.
To enter a frequency from the
MH-48
A6J
keypad, just press the numbered digits in the
proper sequence. There is no “decimal point” key on the
MH-48
A6J
keypad. However,
there is a short-cut for frequencies ending in zero: press the [
#
] key after the last non-zero
digit.
Examples
: To enter 145.520 MHz, press [
1
]
à
[
4
]
à
[
4
]
à
[
5
]
à
[
2
]
à
[
0
]
To enter 145.000 MHz, press [
1
]
à
[
4
]
à
[
5
]
à
[
#
]
If you cannot get the radio to accept the frequency entry, it is possible that
the channel steps are set to an incompatible value (e.g. if you have 25 kHz
steps set, you cannot set a frequency of 145.520 MHz). See page 18 to learn
how to change the channel step size.
3
)
Scanning
From the VFO mode, press the microphone’s [
UP
]/[
DWN
] keys momentarily to initiate
scanning toward a higher- or lower frequency, respectively. The
FT-2980R/E
will stop
when it receives a signal strong enough to break through the squelch threshold. The
FT-
2980R/E
will then hold on that frequency according to the setting of the “Resume” mode
(Menu “
41
SCAN
If you wish to reverse the direction of the scan (i.e. toward a lower frequency, instead of a
higher frequency), just rotate the
DIAL
knob one click in the counter-clockwise direction
while the
FT-2980R/E
is scanning. The scanning direction will be reversed. To revert to
scanning toward a higher frequency once more, rotate the
DIAL
knob one click clockwise.
Press the [
UP
]/[
DWN
] keys again to cancel scanning. You may also press the
PTT
button
momentarily; scanning will stop, but you will not transmit until you release the
PTT
button,
and press it again.
If you have enabled the “Severe Weather Alert” feature, you will occasion-
ally notice “WX” channels interspersed with the regular channels you are
scanning. This is normal, because your radio is constantly monitoring for weather
14
Basic Operation
FT-2980R/E Operating Manual