background image

OxiTop

®

 Box

Overview

ba31112e04

03/2019

5

1

Overview

The OxiTop

®

 Box serves to regulate the temperature of samples on a stirring 

platform, for the determination of the biochemical oxygen demand according to 
the self-monitoring procedure. The OxiTop

®

 Box is especially suitable for the 

inductive stirring platforms IS 6, IS 12 and IS 602, and to incubate samples 
according to the BOD DIN procedure.

The thermostat box is heat insulated and made of stainless steel 1.4301, 
including the interior. The deep-drawn plastic cover hood can easily be opened 
and grants simple and comfortable loading. Inside the box, beside the cold 
evaporator with condensate tub, there is a storing area for 6 methylene blue 
samples. 

A crossflow blower provides permanent air circulation. The temperature is con-
trolled by a precision control system which activates the heating or refrigerating 
system. The refrigeration cycle is hermetically sealed and contains evaporator, 
condenser and an automatically ventilated refrigerating unit. The automatic 
defroster provides constant refrigerating power. 

The power supply of the used stirring platform is provided via the socket inside 
the box. 

To determine BODn and oxygen consumption, a constant tempera-
ture of 20°C ± 1 °C is required.

Bild 1-1

OxiTop

®

 Box with stirring platform IS 12 and sample bottles with OxiTop

®

 

measuring heads

®

IS 12

BSB / BOD / DBO (mg/l)

0-  40

0-  80
0- 200

0- 400

0- 800
0-2000

VOLUME (ml)

432

365
250

164

97
43,5

FACTOR

10

1

2

5

20

50

Summary of Contents for WTW OxiTop Box

Page 1: ...ING MANUAL ba31112e04 03 2019 OxiTop Box OxiTop Box 115 BOD THERMOSTAT BOX IS 12 BSB BOD DBO mg l 0 40 0 80 0 200 0 400 0 800 0 2000 VOLUME ml 432 365 250 164 97 43 5 FACTOR 10 1 2 5 20 50 OPERATING M...

Page 2: ...OxiTop Box 2 ba31112e04 03 2019 Copyright 2019 Xylem Analytics Germany GmbH Printed in Germany...

Page 3: ...urther documents providing safety information 6 2 2 Safe operation 7 2 2 1 Authorized use 7 2 2 2 Requirements for safe operation 7 2 2 3 Unauthorized use 7 3 Commissioning 8 3 1 Scope of delivery 8 3...

Page 4: ...OxiTop Box 4 ba31112e04 03 2019...

Page 5: ...with condensate tub there is a storing area for 6 methylene blue samples A crossflow blower provides permanent air circulation The temperature is con trolled by a precision control system which activ...

Page 6: ...level NOTE indicates a possibly dangerous situation where goods might be damaged if the actions mentioned are not taken 2 1 2 Safety signs on the instrument Note all labels information signs and safe...

Page 7: ...for safe operation The instrument may only be operated according to the authorized use spec ified above The instrument may only be supplied with power by the energy sources mentioned in this operating...

Page 8: ...the instrument with sufficient space for ventilation 2 Connect the cold device plug to the instrument 3 Connect the power plug to a power outlet 4 Switch on the instrument switch on the rear side 5 Fo...

Page 9: ...material The original packing protects the instrument against damage during transport 4 4 Disposal At the end of its operational lifetime the instrument must be returned to the dis posal or return sy...

Page 10: ...our Clean the condenser e g vacuum the ventilation grid Defective Contact the service department Cause Remedy Cause Remedy Ventilation space not sufficient Condenser contaminated Evaporator is frosted...

Page 11: ...missible relative humidity Yearly mean 75 30 days year 95 Other days 85 Power consumption 200 W Starting current OxiTop Box OxiTop Box 115 max 5 A max 10 A Temperature control 20 C 0 5 C Air circulati...

Page 12: ...What to do if OxiTop Box 12 ba31112e04 03 2019...

Page 13: ......

Page 14: ...buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications...