OPERATING MANUAL
ba31112e04 03/2019
OxiTop® Box
OxiTop® Box/115
BOD THERMOSTAT BOX
®
IS 12
BSB / BOD / DBO (mg/l)
0- 40
0- 800- 200
0- 400
0- 8000-2000
VOLUME (ml)
432
365250
164
9743,5
FACTOR
10
1
2
5
20
50
Page 1: ...ING MANUAL ba31112e04 03 2019 OxiTop Box OxiTop Box 115 BOD THERMOSTAT BOX IS 12 BSB BOD DBO mg l 0 40 0 80 0 200 0 400 0 800 0 2000 VOLUME ml 432 365 250 164 97 43 5 FACTOR 10 1 2 5 20 50 OPERATING M...
Page 2: ...OxiTop Box 2 ba31112e04 03 2019 Copyright 2019 Xylem Analytics Germany GmbH Printed in Germany...
Page 3: ...urther documents providing safety information 6 2 2 Safe operation 7 2 2 1 Authorized use 7 2 2 2 Requirements for safe operation 7 2 2 3 Unauthorized use 7 3 Commissioning 8 3 1 Scope of delivery 8 3...
Page 4: ...OxiTop Box 4 ba31112e04 03 2019...
Page 5: ...with condensate tub there is a storing area for 6 methylene blue samples A crossflow blower provides permanent air circulation The temperature is con trolled by a precision control system which activ...
Page 6: ...level NOTE indicates a possibly dangerous situation where goods might be damaged if the actions mentioned are not taken 2 1 2 Safety signs on the instrument Note all labels information signs and safe...
Page 7: ...for safe operation The instrument may only be operated according to the authorized use spec ified above The instrument may only be supplied with power by the energy sources mentioned in this operating...
Page 8: ...the instrument with sufficient space for ventilation 2 Connect the cold device plug to the instrument 3 Connect the power plug to a power outlet 4 Switch on the instrument switch on the rear side 5 Fo...
Page 9: ...material The original packing protects the instrument against damage during transport 4 4 Disposal At the end of its operational lifetime the instrument must be returned to the dis posal or return sy...
Page 10: ...our Clean the condenser e g vacuum the ventilation grid Defective Contact the service department Cause Remedy Cause Remedy Ventilation space not sufficient Condenser contaminated Evaporator is frosted...
Page 11: ...missible relative humidity Yearly mean 75 30 days year 95 Other days 85 Power consumption 200 W Starting current OxiTop Box OxiTop Box 115 max 5 A max 10 A Temperature control 20 C 0 5 C Air circulati...
Page 12: ...What to do if OxiTop Box 12 ba31112e04 03 2019...
Page 13: ......
Page 14: ...buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications...