SonTek – a Xylem brand
FlowTracker2 User’s Manual (January 2019)
27
Handheld
System Information
of the FlowTracker2
includes the following system information,
a) Device (FlowTracker2 Handheld),
b) Serial Number (123456),
c) Upgraded Firmware (V0.14.7).
d)
To navigate to Main Menu or Probe Information,
i).
Main Menu – Press the Left Soft Key,
ii).
Probe Information – Press the Right Soft Key.
Figure 2:8 - Handheld System
Information
Probe
System Information
of the FlowTracker2
includes the following system information,
a) Device (FlowTracker2 Probe),
b) Serial Number (123456),
c) Probe Firmware (V0.14.7),
d) Number of Beams (2 or 3).
e)
To navigate to Main Menu,
i).
Press the Left Soft Key two times.
Figure 2:9 - Probe System
Information
Measurement (Main Menu)
2.5.5
The
Measurement
function is the main component of the FlowTracker2 handheld
software and includes two measurement modes. The Discharge mode is for applications
where the primary goal is to measure river/stream discharge. The technique involves
taking a series of velocity measurements at different locations throughout the cross
section. These measurements are combined with location and water depth information to
compute the total discharge. The General mode is designed to perform a series of
velocity measurements at different locations, but does not provide discharge as an
output.
The methods and techniques implemented for determining the mean station velocity,
calculation of discharge and uncertainty analysis of a measurement are based on the
following literature,
•
ISO 748 – 2007, Hydrometry - Measurement of liquid flow in open channels using
current meters or floats,
•
WMO-No. 1044, Volume I – Fieldwork, 2010.
•
IVE, Quantifying Uncertainty in Discharge Measurements: A New Approach
Summary of Contents for SonTek FlowTracker2
Page 107: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 106 ...
Page 117: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 116 ...
Page 196: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 195 ii Stationary Measurement ...
Page 247: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 246 Configuration Changes ...
Page 283: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 282 ...
Page 300: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 299 ...