6  Operation

6.1  Configure and install the optimyze sensors

Follow the optimyze Quick Start Guide to configure optimyze sensors before setting up

Gateway.

6.2  Set up optimyze Gateway

1. Connect the antennas present in the packaging while paying attention to the insert on the

Gateway (each antenna corresponds to a specific insert on the Gateway).

2. Connect Gateway to power supply.
3. Turn on Gateway with the 

Power switch.

4. The Gateway will connect to the cellular network and xylem cloud. Note that this could

take a few minutes. Once it successfully connects, the red LED goes from blinking to a

solid red state and green LED will also turn on. Blue LED starts blinking with 5 second

interval.

5. To pair with optimyze sensors:

a) Put the first optimyze sensor in configuration mode by positioning the magnet

supplied with the sensor over the Bluetooth symbol until the LED blinks pink.

b) Once the sensor is in configuration mode, press Bluetooth button on the optimyze

Gateway. Blue LED starts blinking with a one second interval indicating pairing mode

is active. Pairing mode is active 90 seconds.

c) The Gateway will now attempt to pair with the sensor. Successful pairing will be

indicated by a blue LED triple blink on the Gateway.

d) Once paired, the Gateway will then finalize the connection with the sensor. This will

take approximately 10 seconds and will be indicated by a solid blue LED on the

Gateway. Pairing is complete when the Blue LED starts to blink at 1 second intervals.

e) After the MG100 leaves pairing mode, to connect another sensor, repeat steps (a)

through (d).

f) Once paired, the Gateway connects to the optimyze sensors every 24 hours.

6.3  Unpairing

If the button is pressed and held for 30 or more seconds, upon release the Gateway will

delete all BLE pairing information. A successful unpairing will be indicated with a double-

blink of the blue LED.

6  Operation

optimyze

 Gateway Instruction, Operation, and Maintenance Manual

9

Summary of Contents for optimyze

Page 1: ...Instruction Operation and Maintenance Manual P2007090 Rev 1 optimyze Gateway...

Page 2: ......

Page 3: ...ns 7 4 2 LEDs 7 5 Installation 8 5 1 Precautions 8 5 2 Mounting options 8 6 Operation 9 6 1 Configure and install the optimyze sensors 9 6 2 Set up optimyze Gateway 9 6 3 Unpairing 9 7 Troubleshooting...

Page 4: ...11 Certifications 17 11 1 For U S 17 11 2 For Canada ISED 18 11 3 UK UKCA 18 11 4 EU Regulatory 18 Table of Contents 2 optimyze Gateway Instruction Operation and Maintenance Manual...

Page 5: ...fety terminology and symbols About safety messages It is extremely important that you read understand and follow the safety messages and regulations carefully before handling the product They are publ...

Page 6: ...t and safety devices Use personal protective equipment as needed Examples of personal protective equipment include but are not limited to hard hats safety goggles protective gloves and shoes and breat...

Page 7: ...e packing materials from the product Dispose of all packing materials in accordance with local regulations 2 To determine whether any parts have been damaged or are missing examine the product 3 If th...

Page 8: ...Compact Form Factor 110 3 mm 4 4 in x 99 2 mm 3 9 in x 35 4 mm 1 4 in Visual status indication LED Clear indication of optimyze Gateway status See Button locations on page 7 for different status info...

Page 9: ...elow LED color LED Description Blue 5 second single blink Normal mode 1 second blink Pairing mode On Connected over Bluetooth to optimyze sensor Triple blink Successful new Bluetooth pairing with an o...

Page 10: ...ng the unit on a vertical surface The screw head diameter can be no larger than 7 mm with a maximum thread diameter of 3 75 mm and a head height of 3 2 mm When the screw is installed in the mounting s...

Page 11: ...ED blinks pink b Once the sensor is in configuration mode press Bluetooth button on the optimyze Gateway Blue LED starts blinking with a one second interval indicating pairing mode is active Pairing m...

Page 12: ...y because of lacking network coverage optimyze sensor is in configuration mode and Gateway is in pairing mode but they are not pairing optimyze sensor may not be in pairing range 6 sensors may already...

Page 13: ...95 non condensing Power supply Feature Value Operating location Indoor use Operating environment Non hazardous non corrosive Operating temperature 0 C to 40 C 32 F to 104 F Storage temperature 20 C to...

Page 14: ...ature Value Weight for Gateway boxed kit without power supply 0 518 lbs 0 24 kg Weight for Power Supply 0 300 lbs 0 14 kg 8 7 Part numbers Part Part number optimyze Gateway w USB cable P2007065 Power...

Page 15: ...Warranty are warranted only for the balance of the warranty period on the parts that were repaired or replaced Seller shall have no warranty obligations to Buyer with respect to any product or parts...

Page 16: ...ecurity is governed through a three lines of defense model that includes product developers product security engineers and audit staff 10 2 Security Recommendations for End User optimyze Gateway has b...

Page 17: ...erations confirmed tampering or theft of the device Devices are hardened and Xylem provides PSIRT to help customers investigate potential security incidents This safeguard supports the ability to trac...

Page 18: ...hp Mitigations 2 NIST SP 800 53 Rev 5 available online https nvlpubs nist gov nistpubs SpecialPublications NIST SP 800 53r5 pdf 3 ISA IEC 62443 standards available for purchase from ISA IEC or ANSI 10...

Page 19: ...harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause har...

Page 20: ...ding Digital Apparatus Based on this evaluation this product continues to observe compliance to the requirements set forth by The Innovation Science and Economic Development Canada ISED and complies w...

Page 21: ...Page left intentionally blank...

Page 22: ...Page left intentionally blank...

Page 23: ...Page left intentionally blank...

Page 24: ...customers who know us for our powerful combination of leading product brands and applications expertise with a strong focus on developing comprehensive sustainable solutions For more information on h...

Reviews: