![Xylem Lowara Scuba Dry Series Additional Installation, Operation And Maintenance Instructions Download Page 33](http://html1.mh-extra.com/html/xylem/lowara-scuba-dry-series/lowara-scuba-dry-series_additional-installation-operation-and-maintenance-instructions_4255371033.webp)
en – Original Instructions
SCUBA DRY – Additional Installation, Operation and Maintenance Instructions
33
8
Technical Information
8.1
Operating environment
Non-aggressive, non-explosive atmosphere, and not subjected to frost.
Temperature of pumped liquid
0 to 40°C (32 to 104°F).
NOTICE:
If the temperature exceeds the stated limits, contact Xylem or the Authorised Distributor.
Suspended impurities
Model
Maximum diameter, mm (in)
1SCD(S)
≤
1.0 (0.04)
3SCD(S), 5SCD(S), 8SCD(S)
≤
2.0 (0.08)
Chloride concentration
≤
200 ppm at 20°C (68°F).
Sand quantity
≤
25 g/m
3
.
8.2
Maximum head
50 Hz
Model
Head, m (ft)
Model
Head, m (ft)
Model
Head, m (ft)
1SCD..9/09/5C
75 (245)
3SCD..8/15/5T
90 (294)
5SCD..5/09/5T
59 (193)
1SCD..7/07/5C
60 (197)
3SCD..7/09/5T
79 (258)
5SCD..4/07/5T
48 (156)
1SCD..6/05/5C
101 (331)
3SCD..5/07/5T
58 (190)
5SCD..3/05/5T
36 (117)
1SCD..9/09/5T
78 (257)
3SCD..4/05/5T
47 (153)
8SCD..6/15/5C
65 (214)
1SCD..7/07/5T
61 (201)
5SCD..8/15/5C
93 (304)
8SCD..3/09/5C
32 (104)
1SCD..6/05/5T
102 (335)
5SCD..6/11/5C
70 (228)
8SCD..2/05/5C
21 (69)
3SCD..9/15/5C
91 (298)
5SCD..5/09/5C
59 (195)
8SCD..6/22/5T
66 (215)
3SCD..8/11/5C
78 (255)
5SCD..4/07/5C
47 (156)
8SCD..5/15/5T
55 (179)
3SCD..7/09/5C
57 (186)
5SCD..3/05/5C
35 (116)
8SCD..4/11/5T
44 (144)
3SCD..5/07/5C
45 (149)
5SCD..8/22/5T
94 (309)
8SCD..3/09/5T
33 (108)
3SCD..4/05/5C
101 (331)
5SCD..7/15/5T
83 (271)
8SCD..2/05/5T
22 (72)
3SCD..9/22/5T
75 (245)
5SCD..6/11/5T
71 (232)
-
-