5 System Description
5.1 User interface
11
7
8
9
2 10
1
3
6
4
5
Figure 7: User interface
Number
Description
1
This button is used to switch between AUTOMATIC and MANUAL Mode.
In AUTOMATIC Mode, the controller operates the pump to maintain the
pressure setpoint.
In MANUAL Mode, the controller operates the pump based on the
Start/Stop button.
2
This button is used for the Start/Stop function.
In MANUAL Mode: To run the pump, press and hold the button. The
pump ramps down to stop when the button is released.
In AUTOMATIC Mode: Press to exit AUTOMATIC mode and enter
MANUAL mode. If the pump is running, it ramps to stop.
3
This button is used to access the BASIC MENU parameters in MANUAL
mode. See BASIC MENU (MB) parameters on page 12.
4 and 5
These two buttons are used for:
• Decreasing or increasing the value of a parameter that is selected
in the BASIC MENU (MB) or ADVANCED MENU (MA).
• Viewing the operating parameters in AUTOMATIC mode. See
operating parameters on page 10.
6
This button is used for saving and selecting the next parameter in any
MENU. In MANUAL mode, this button is an alarm reset button.
7
Power LED:
Steady green LED, indicates the power is on and the controller is active.
8
Error LED:
Steady red LED, indicates a fault. The LED is illuminated when there is
an alarm.
9
Start/Stop LED:
Steady yellow LED, indicates the pump is running.
10
Mode LED:
• Illuminated green and steady in Automatic mode.
• Flashing green in manual parameter configuration mode (Basic
Menu, Advanced Menu)
11
Display for showing operating parameter, menu parameters, or fault
codes.
5 System Description
16
ResiBoost INSTRUCTION MANUAL