9 Technical Reference
9.1 Motor data
The drive unit includes a synchronous motor with IE4 equivalent efficiency.
NOTICE:
Do not connect a starter or a Variable Frequency Drive (VFD) to this unit.
Feature
Description
Input frequency
50–60 Hz
Input supply
3-phase
• 380–480 V
• 200–240 V
Maximum starts per hour
Pump only: 60
Pump with gateway or controller: 240
Design in applicable parts
According to IEC 60034–1
Voltage variation
• Continuously running: Maximum ±5%
• Intermittently running: Maximum ±10%
Voltage imbalance between the phases
Maximum of 2%
Stator insulation class
In accordance with class H (180°C, 356°F)
9.2 Application limits
Data
Description
Liquid temperature
Maximum 40°C (104°F)
Liquid density
Maximum 1100 kg/m3 (9.2 lb per US gal)
pH of the pumped liquid
5.5–14
Depth of immersion
Maximum 20 m (65 ft)
9.3 Minimum permitted liquid level
In hazardous areas, this information is critical for the safety of the installation of this
product.
The pump housing (volute) must be filled with water before starting the pump, and during
operation.