![Xylem Flygt Concertor 6020 Installation, Operation And Maintenance Manual Download Page 50](http://html1.mh-extra.com/html/xylem/flygt-concertor-6020/flygt-concertor-6020_installation-operation-and-maintenance-manual_892131050.webp)
10 Technical Reference
10.1 The pump
10.1.1 Motor data
The drive unit includes a synchronous motor with IE4 equivalent efficiency.
NOTICE:
Do not connect a starter or a Variable Frequency Drive (VFD) to this unit.
Feature
Description
Input frequency
50–60 Hz
Supply
3–phase, 380–480 V
Maximum starts per hour
240
Design in applicable parts
According to IEC 60034–1
Voltage variation
• Continuously running: Maximum ±5%
• Intermittently running: Maximum ±10%
Voltage imbalance between the phases
Maximum of 2%
Stator insulation class
In accordance with class H (180°C, 356°F)
10.1.2 Application limits
Data
Description
Liquid temperature
Maximum 40°C (104°F)
Liquid density
Maximum 1100 kg/m3 (9.2 lb per US gal)
pH of the pumped liquid
5.5–14
Depth of immersion
Maximum 20 m (65 ft)
10.2 The gateways
10.2.1 Dimensions
RS485
DI
1
2
3
4 GND
A
AI
AO
HMI
1
2
3
4
5
B
GND
24VDC
+
_
+
_
+
_
PWR
DI1
DI2
DI3
DI4
DO1
DO2
DO3
DO4
ALARM A
ALARM B
PUMP RUN/CLEAN
PUMP COMMS
RS485
USB
NODE
ADDRESS
ON
OFF
MASTER
SLAVE
TERM
PUMP
DO1
NO COM NO COM
T4
T3
GND
DO2
DO3
NO COM NO COM
DO4
ETHERNET
Concertor™
FPG 411
1 2
3
4 5
6
7
8
9
0
1
2
3
WS009746A
1. 112 mm (4.4 in)
2. 45 mm (1.8 in)
3. 106 mm (4.2 in)
10.2.2 Environmental requirements
Parameter
Value
Operating temperature
-20°C – +60°C (-4°F – 140°F)
Storage temperature
-20°C – +85°C (-4°F – 185°F)
10 Technical Reference