2
1
WS008551A
1. Terminal plate unit
2. Starter unit
6. Disconnect the stator leads.
4.5.11 Remove the stator
1. Lift the stator housing.
2. Place a protective material underneath to prevent the stator from breaking when
released.
3. Use an LP gas set to heat the stator housing quickly and evenly, until the stator drops.
Do not allow the stator housing temperature to exceed 150°C (302°F).
CAUTION: Thermal Hazard
Allow surfaces to cool before starting work, or wear heat-protective
clothing.
WS002667A
4. When the stator is released and has dropped down, allow the stator housing and the
stator to cool.
If the new stator is ready to be installed, then check that the stator housing is 150°C
(302°F). If it is, then install the new stator without allowing the stator housing to cool
down.
4.6 Assemble the pump
4.6.1 Assembly overview
The following flowchart shows the general workflow for assembling the pump.
Stator
↓
Electrical connections, cable entry
↓
4 Maintenance
2640.181/.281 Service and Repair Instructions