6.4.1 Remove the impeller, drainage version
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.
1. Remove the strainer.
WS002031A
3x
2. Remove the diffuser.
WS002032A
3. Remove the impeller:
a) Remove the impeller screw and washer.
b) Pull off the impeller.
6 Maintenance