Sensor
Terminal block Conductor
number for 12-
lead cable
Conductor for
24-lead cable
Pt100 in the stator winding 1
19
8
8
4
—
—
Pt100 in the stator winding 2
21
—
13
22
—
14
Pt100 in the stator winding 3
23
—
15
24
—
16
Memory module RS-485 B
74
9
9
Memory module RS-485 A
75
10
10
Memory module supply, ground (earth)
76
11
11
Memory module supply, 12 VDC+
77
12
12
Vibration sensor VIS 10
+ 78
—
21
– 79
—
22
4.5.5 Power cable phase sequence
In the following figure, the triangle marked “L1,” “L2” and “L3” shows the phase sequence.
L2
L1
L2
L3
L3
L1
WS000578E
1
2
3
4
T2
T1
7
6
5
8
Figure 15: Correct phase sequence
Item
Description
1
L1 cable lead
Brown
2
L2 cable lead
Black
3
L3 cable lead
Gray
4
Earth PE or ground lead cable
5
T1 cable lead (control element)
In cables with both power conductors and
control element.
MAS 801: See the SIO manual for T1, T2,
and drain wire connections.
6
T2 cable lead (control element)
7
Screen (drain wire)
8
Power cable to unit
4.5.6 Identifying signal leads connected to the PEM, thermal contacts, or thermistors
This section is for pumps with the MAS 801
™
.
There can be 1–4 SUBCAB cables. Each cable contains both power conductors and signal
conductors. Only the signal conductors from one cable are used.