Perform this step immediately after start-up in order to prevent damage to the pump
from operating with zero flow.
5.5 Pump operation checklist
CAUTION:
Vary the capacity with the regulating valve in the discharge line. Never throttle the flow
from the suction side since this can result in decreased performance, unexpected heat
generation, and equipment damage.
Requirement
Description
Checked
Driver/pump rotation
Check the rotation each time you reconnect the motor leads.
Be sure that the driver operates in the direction indicated by
the arrow on the pump casing. Rough operation and
extreme vibration can result if you operate the pump in the
wrong direction.
Flow
An accurate measurement of flow rate (volume/time) is
difficult in the field. Venturi meters, flow nozzles, orifice
plates, or timing the draw down in the wet well are all
possible methods. Record any reading for future reference.
Pressure
Check and record both suction and discharge pressure
gauge readings for future reference. Also record voltage,
amperage per phase, and pump speed. You can also record
the kilowatts if you have an available indicating wattmeter.
Temperature
Check and record bearing temperatures using a
thermometer. Make sure that temperatures do not exceed
250°F (121°C).
Vibration
The acceptable vibration level of a centrifugal pump
depends on the rigidity of the pump and the supporting
structure. Refer to the Hydraulic Institute Standards for a
complete description and charts on various pumps.
Sound
Field sound levels are difficult to measure because of
background noise from piping, valves, drivers, and gears.
Follow the recommendations in the Hydraulic Institute
Standards.
Output
Make all pump output adjustments with the discharge
valves.
5.6 Shut down the pump
WARNING:
Always disconnect and lock out power before servicing to prevent unexpected startup.
Failure to do so could result in death or serious injury.
1. Shut down the pump driver.
Consult the manufacturer instructions for special operations.
2. Close the suction and discharge valves.
5 Commissioning, Startup, Operation, and Shutdown