P
A
R
1
1
2
3
A
Angular alignment
P
Parallel alignment
1
Dial indicators
2
Index line
3
Resilient separator
Figure 7: Pump alignment via dial indicator
d) Set the dial to zero.
e) Rotate both coupling halves together and make sure that the index lines remain
matched.
f) Reposition the equipment until the offset is within the permissible value.
2. Check the parallel misalignment:
a) Mount the dial indicator base to one coupling half, or shaft.
b) Position the dial indicator button on the outside diameter of the opposite coupling
half.
c) Set the dial to zero.
d) Rotate both coupling halves together and make sure that the index lines remain
matched.
e) Reposition the equipment until the offset is within the permissible value.
4.3.4 Maximum allowable coupling misalignment
TB Wood’s
®
Dura-Flex
®
Couplings
TB Wood’s
®
Dura-Flex
®
elastomeric coupling alignment guidelines shown are also listed
in the coupling service manual published by TB Wood’s
®
. Refer to the service manual for
more detailed information regarding fastener torque values, detailed installation
instructions, and more.
The following figure defines the allowable parallel gap for a given degree of angular
misalignment.
4 Installation