Figure 1: Sample pump end only lifting diagram
Pump, base, and driver lifting procedure for bases with lifting holes
1. Using ANSI/OSHA Standard “S” hooks, place the “S” hooks in the holes located in the
four corners of the base. Ensure the points of the hooks do not touch the bottom of the
pump base.
2. Attach nylon slings, chains, or wire rope to the “S” hooks. Size lifting equipment
appropriately for the load and ensure the lift angle will be less than 45° from vertical.
Pump, base, and driver lifting procedure for bases without lifting holes
1. Using nylon slings, chains, or wire ropes, place the slings around the suction and
discharge ports in a similar fashion as indicated in Figure 1.
2. Place another sling around the back end of the motor as close to the mounting feet as
possible. Make sure the sling does not damage the housing cover or conduit box.
3. Join the free ends of the slings together and place over an ANSI/OSHA Standard “S”
hook. Ensure the slings are secure such that they will not slip while lifting.
Notes:
• Size lifting equipment appropriately for unbalanced loading. Motors may or may not
be mounted at the factory.
• Pump, base, and driver assemblies where the base length exceeds 100 in. (2540 mm)
may not be safe to lift as a complete assembly. Damage to the baseplate may occur.
• If the driver has been mounted on the baseplate at the factory, it is safe to lift the entire
assembly.
• If driver has not been mounted at the factory and the overall baseplate length exceeds
100 in. (2540 mm), do not lift the entire assembly consisting of pump, base, and driver.
Instead, lift the pump and baseplate to its final location without the driver. Then mount
the driver.
• Bases are supplied with lifting holes in the sides or ends of the base.
2.3 Pump storage requirements
Storage requirements depend on the amount of time that you store the unit. The normal
packaging is designed only to protect the unit during shipping.
Length of time in storage
Storage requirements
Upon receipt/short-term (less than six months)
• Store in a covered and dry location.
• Store the unit free from dirt and vibrations.
2 Transportation and Storage
8
e-XC INSTRUCTION MANUAL