INSTRUCTION MANUAL 

210711

D

 

Bell & Gossett

® 

Zone Trol II

Model Z-1 

c@us 

LISTED 

INSTALLER: 

PLEASE LEAVE THIS MANUAL FOR THE OWNER'S USE. 

h.

SAFETY

..  INSTRUCTION 

This safety alert symbol will be used in this manual and on the 

unit safety instructions decal to draw attention to safety related 

instructions. When used, the safety alert symbol means 

ATTEN­

TION!  BECOME  ALERT!  YOUR  SAFETY IS  INVOLVED! 

FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT 

IN A SAFETY HAZARD. 

DESCRIPTION 

The Bell & Gossett ZoneTrol 11 is designed to control 120 VAC 

circulating pumps in hydronic systems. 

Max. 

T-stat

Number of 

Max. 

Model 

Current

Zones 

HP/Pump 

Z-1

0.085 

1/3 

LED DEFINITION 

Power  LED will  illuminate  when input  power  is  applied  to the 

controller. Zone LED will illuminate when relay is energized. 

MECHANICAL INSTALLATION 

INSTRUCTIONS 

The  pump  controller  should  be  securely  mounted  on  a  wall 

near the pumps using four #8 screws (not included). 

ELECTRICAL INSTALLATION 

INSTRUCTIONS 

A

WARNING: Electrical Shock Hazard 

Electrical  connections  are  to  be  made  by a  qualified 

electrician  in  accordance  with  all  applicable  codes,  ordi­

nances  and  good  practices  Disconnect  and  lock  out  the 

power before making electrical connections.  Failure to fol­

low these instructions could result in serious personal injury 

and/or death. 

1. Disconnect  the  electrical  supply  to  the  pump  before

installing the controller.

2. Refer to the applicable wiring diagram

- Figure 1: Cold Start Boiler

- Figure 2: Tankless Coil

3. Verify  that  the circulator(s) do not exceed  the electrical  rat­

ing of the controller.

4. Make  electrical  connections  according  to  the  applicable

wiring diagram.  Run  the pump power through  the holes in

the controller chassis to the applicable UN terminals.  Keep

120 VAC  and  24  VAC  wiring  separate.  All  120  VAC  wiring

should be 14 AWG (minimum) copper electrical.  Perform all

wiring in accordance with applicable codes.

5. Run  the  thermostat  wires  through  the  grommet(s)  in  the

controller chassis and connect to the appropriate  R/W ter­

minals.  Keep 24 VAC wiring separate from 120 VAC wiring.

A

WARNING: Electrical Shock Hazard 

When wiring per  the Tankless Coil Application,  pump 

controller and boiler aquastat must be on the same circuit 

and  have  a  common  disconnect.  Failure  to  follow  these 

instructions  may  introduce  a  secondary  source  of  power 

resulting in personal injury or death. 

This product can expose you to chemicals including 

Lead, which is known to the State of California to 

cause cancer and birth defects or other reproductive harm.

For more information go to: www.P

6

5Warnings.ca.gov.