background image

inside

USER'S MANUAL

STEREO POWER AMPLIFIER

XA500/XA1000

ENGLISH

POWER ON

OPERATING

PROTECTION

LIMIT

CLIP

CH1

CH1

CH2

CH2

ON

OFF

0dBV

0dBV

Italian Style

-

-

-

Italian Style

Summary of Contents for XA1000

Page 1: ...insideUSER S MANUAL STEREO POWER AMPLIFIER XA500 XA1000 ENGLISH POWER ON OPERATING PROTECTION LIMIT CLIP CH1 CH1 CH2 CH2 ON OFF 0dBV 0dBV Italian Style Italian Style ...

Page 2: ... as lighted candles should be placed on the apparatus IMPORTANT SAFETY INSTRUCTIONS Read these instructions Heed all warnings Follow all instructions Keep these instructions Only use attachments accessories specified by the manu facturer Power Cord and Plug Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A groun...

Page 3: ...like to share with you our work and our dreams paying attention to your suggestions Following this idea we create our products and we will create the new ones From our side we guarantee you and we will guarantee you also in future the best quality and the best fruits of our continuous researches and the best prices Our XXL XA500 1000 Stereo Power Amplifier is the result of many hours of listening ...

Page 4: ... 1 INTRODUCTION 4 2 FEATURES 4 3 CONTROL ELEMENTS 5 3 1 The Front Panel 3 2 The Rear Panel 4 APPLICATION 8 4 1 Stereo Mode 5 TECHNICAL SPECIFICATIONS 11 6 WARRANTY 12 4 2 Bridge Mode USER S MANUAL inside 3 XA500 XA1000 ...

Page 5: ...tions An automatic speed fan matches cooling capacity with heat requirements The amplifier frame contains all solid state circuitry using complementary silicon output devices The amplifier is supplied with a single moulded AC cord having an appropriate AC plug for the intended operating voltage The amplifier employs forced air cooling with a variable speed fan for minimum acoustic noise Air flow i...

Page 6: ... Led This Led lights up when the unit is powered Level Control for Channels 1 2 Adjust the output signal level to avoid signal distortion 3 2 Rear Panel 1 2 3 5 4 6 12 7 8 11 13 9 10 POWER ON OPERATING PROTECTION LIMIT CLIP CH1 CH1 CH2 CH2 ON OFF 0dBV 0dBV Italian Style 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 2 3 Apparaten skall anslutas till jordat uttag nar den ansluts till ett natverk CH1 CH2 BRI...

Page 7: ...vel control of channel 2 should be turn down to smallest Fan The fan can accelerate the flow of air to lower the temperature inside unit The inside temperature determines the fan speed which controls the inside air flowing speed Power Source Socket It is used to connect power cord after setting the proper voltage connect one end of power cord with the unit and another end with mains Manual Reset P...

Page 8: ...input into channel 2 can be output from channel 2 only Total two optional modes Please see following diagram for connecting the power amplifier into your audio system 1 2 3 GND INPUT Input Connector Balanced Channel 1 Channel 2 1 2 3 GND INPUT MODE Release this button Input Connector Balanced Channel 2 Channel 1 Channel 1 Channel 2 MODE Release this button Channel 1 Channel 2 1 2 3 2 1 3 NEW TIDE ...

Page 9: ... till ett natverk CH1 CH2 BRIDGE MONO BREAKER PARALLEL OUTPUT PARALLEL OUTPUT OUTPUT2 OUTPUT1 POWER OUTPUTS CH1 1 1 POS NEG CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG TIP PIN 2 RING PIN 3 SLEEVE PIN 1 TIP PIN 2 RING PIN 3 SLEEVE PIN 1 MODE BRIDGE STEREO INPUT CH2 CH1 LIMITER OFF ON 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 2 3 Apparaten skall anslutas till jordat uttag nar den ansluts till ett...

Page 10: ... 1 1 POS NEG CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG TIP PIN 2 RING PIN 3 SLEEVE PIN 1 TIP PIN 2 RING PIN 3 SLEEVE PIN 1 MODE BRIDGE STEREO INPUT CH2 CH1 LIMITER OFF ON 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 2 3 Apparaten skall anslutas till jordat uttag nar den ansluts till ett natverk CH1 CH2 BRIDGE MONO BREAKER PARALLEL OUTPUT PARALLEL OUTPUT OUTPUT2 OUTPUT1 POWER OUTPUTS CH1 1 1 POS ...

Page 11: ...anslutas till jordat uttag nar den ansluts till ett natverk CH1 CH2 BRIDGE MONO BREAKER PARALLEL OUTPUT PARALLEL OUTPUT OUTPUT2 OUTPUT1 POWER OUTPUTS CH1 1 1 POS NEG CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG TIP PIN 2 RING PIN 3 SLEEVE PIN 1 TIP PIN 2 RING PIN 3 SLEEVE PIN 1 MODE BRIDGE STEREO INPUT CH2 CH1 LIMITER OFF ON 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 2 3 Apparaten skall anslutas ...

Page 12: ...anced 56 36dB FRONT AC SWITCH CH1 CH2 GAIN KNOBS Continuously variable speed fan rear to front air flow On off muting DC fault load grounding relay Internal fault fuses 200 240 100 120 Vac 50 60Hz 19 48 3 cm rack mounting 3 5 8 9 cm tall 2 rack spaces 15 9 40 cm deep rack mounting to rear support ears 11Kg 190W 300W 600W Indicators 1 per channel Connectors each channel Cooling Load Protection Powe...

Page 13: ... the purchase date if you have completed the Warranty Registration Card in time 3 3 During the warranty service XXL may repair or replace this product at its own option at no charge to you for parts or for labor in accordance with the right side of this limited warranty 3 4 This warranty does not apply to the damages to this product that occurred as the following conditions Normal tear and wear In...

Page 14: ... 39 055 5040002 Fax 39 055 5040460 Web site www x x l it E mail info x x l it New materials and design refinements are introduced into existing products without previous notice Present XXL Systems may differ in some respects from those presented in this brochure NF01809 1 0 inside XA500 XA1000 USER S MANUAL ...