background image

Professional Pan Tilt Zoom 

IR Speed Dome Camera

Version 1

User Guide

Thank you purchasing the speed dome camera from Xvision.

Please ensure that you read and understand this User Guide before operating the camera.

 

Please store this Installation Guide in an easily accessible location.

MODELS:

 XHC1080S10IRN and XHC1080S27IRN

HD

1080P

PRO

Summary of Contents for XHC1080S10IRN

Page 1: ...de Thank you purchasing the speed dome camera from Xvision Please ensure that you read and understand this User Guide before operating the camera Please store this Installation Guide in an easily accessible location MODELS XHC1080S10IRN and XHC1080S27IRN HD 1080P PRO ...

Page 2: ...ocol Baud rate setting 8 Address setting 8 Baud rate setting 9 Protocol setting 10 Main Menu OSD Tree 11 Function settings 12 Set call preset 12 Set preset position 12 Call preset 12 Calling Tours Cruise 12 Calling auto tour line 13 Stay time 13 Clear cruise routes 14 Limit scan 14 Setting Limit scanning on left and right 14 Calling Limit scan 14 360 horizontal scanning 15 Pattern scan 15 ...

Page 3: ...nal boundary of living quarters etc As a high end monitoring product the XHC1080S10IRN and XHC1080S27IRN features strong stable and reliable functions in addition to easy operation and installation This camera has many functions such as fast trace 360 unlimited rotation 180 automatic overturn area scan preset location scan and pattern scan This camera applies to watching a moving target in a big a...

Page 4: ...mit an abnormal smell of smoke please immediately stop it shut off the power and contact your supplier Please do not place this equipment near a heat source to avoid risk of fire Please do not store install and use this product in danger areas with inflammable or explosive substances Please make sure the power is turned off when installing the product Please do not use the PTZ in an environment wh...

Page 5: ...X v i s i o n c o m P a g e 5 30 Package contents The contents for the XHC1080s20IRN and XHC1080S27IRN are shown below ...

Page 6: ...X v i s i o n c o m P a g e 6 30 Installation ...

Page 7: ...ce 3 IR range 70M 4 Highest ESD protection against lightning and power surges 5 HD1080P AHD output 7 IP66 Protection grade IP66 XHC1080S27IRN Camera HD AHD 1080P 2 0Mpixes 1 3 CMOS Sensor 27x f 4 7mm 90 0mm D N ICR Cut DWDR Color 0 1lux B W 0 01lux Dome Features 1 New 32 bit processor with soft ID more storage space higher speed better performance lower consumption 2 Imported array IR LED auto adj...

Page 8: ...n set the address the Protocol and the baud rate manually There is a removable plate under the ball cover which you can open and close at any time Open the plate you will see an 8 bit dial switch move the dials 1 8 up to set address code of the dome Address setting No 1 No 8 are used to set the address codes you can set address codes within the range 1 255 factory default is 1 Use binary in the ta...

Page 9: ...0 52 000100 00 8 111010 00 23 011001 00 38 10101 100 53 100100 00 9 000110 00 24 111001 00 39 01101 100 54 010100 00 10 100110 00 25 000101 00 40 11101 100 55 110100 00 11 010110 00 26 100101 00 41 00011 100 56 001100 00 12 110110 00 27 010101 00 42 10011 100 57 101100 00 13 001110 00 28 110101 00 43 01011 100 58 011100 00 14 101110 00 29 001101 00 44 11011 100 59 Baud rate setting The baud rate i...

Page 10: ...s 2400 bps 4800 bps 9600 bps 19200 bps No 4 OFF ON OFF ON No 5 OFF OFF ON ON Protocol setting There is no need to set the Protocol to match your DVR Controller as this is Adaptive and will auto sense what your device is set to You don t need to set PELCO_D PELCO_P support PELCO_D and PELCO_P ...

Page 11: ...X v i s i o n c o m P a g e 11 30 Main Menu OSD Tree You can call preset 103 to bring up the PTZ OSD menu ...

Page 12: ...ing the PTZ IR dome camera you will find different buttons Press the key set preset Set Enter 1 or the required Preset number you wish Press the key enter to save the preset Call preset Press the key call preset position or Preset Then press the required preset number 1 Click Enter This will move your PTZ camera to the stored preset location Calling Tours Cruise Tours Cruise enable you to set a de...

Page 13: ...preset 16 35 preset Stay time You can set how long the Tour will stay on a preset this can be set between 5 to 60 Seconds Call the preset No 123 the stay time add 5 sec call No 124 preset position the stay time minus 5 sec stay time operation default 10 sec Call No 106 clear all Settings to restore the default Add 5 sec Call No 123 preset Minus 5 sec Call No 124 preset Example using the DVR or con...

Page 14: ...eset position Move the PTZ camera to the Left limit position you require and set No 84 preset position The Speed dome will run just between these two points only Example Using the DVR or controller Press the key set preset Then move the camera to the Right position Enter 83 Press the key enter Move the PTZ Speed dome to the required Left position Enter 84 Press the key enter Calling Limit scan Cal...

Page 15: ... dome will start to Scan 360 horizontal scanning Pattern scan This product has 4 groups of pattern scan Pattern scanning is used when you have an irregular pattern that you want patrolled this does not use preset positions but recorded moves using the Controller or DVR controls Move to the target location then call No 113 preset position to start recording scanning track Move the controller or DVR...

Page 16: ... preset call No 108 preset second The start point call No 115 preset The end point call No 116preset call No 109 preset third The start point call No 117 preset The end point call No 118 preset call No 110 preset fourth The start point call No 121 preset The end point call No 122 preset call No 111 preset Call No 106 preset to clear all Settings to restore the default to clear Limit scanning 360 h...

Page 17: ... Call 105 RATIO SPEED ON and OFF Call 106 Clear all settings to restore the default Call 107 Horizontal start position fix Set 125 Set home position Call 125 Clear Home position Call 126 Increase 1 minute for home position Max 10 minutes Call 127 Decrease 1 minute for Home position Min 1 minute Tour Fast Call Up Function Call 96 Run tour 3 16 30 preset Call 97 Run tour 2 6 15 preset Call 98 Run to...

Page 18: ...ll Up Function Fast Call Up Function Call 108 Run pattern scan 1 Call 113 start recording scanning track 1 Call 114 end of recording scanning track 1 Call 109 Run pattern scan 2 Call 115 start recording scanning track 2 Call 116 end of recording scanning track 2 Call 110 Run pattern scan 3 Call 117 start recording scanning track 3 Call 118 end of recording scanning track 3 Call 111 Run pattern sca...

Page 19: ...trol PTZ camera Call 130 preset point could release the lock Call 131 Lock PTZ camera movement Call 132 Park mode increase time You can set the PTZ speed dome to go back to a command i e tour cruise pattern mode after a set time or no interaction The default time is 5 minutes User can increase the time by calling 132 preset point Each calling operation increase 1 minute Calling 133 preset point to...

Page 20: ...et call 1 ZOOM OSD ON Set 254 preset call 17 HLC OFF Set 254 preset call 2 ZOOM OSD OFF Set 254 preset call 18 HLC level 1 Set 254 preset call 3 Through fog OFF Set 254 preset call 19 HLC level 2 Set 254 preset call 4 Through fog level 1 Set 254 preset call 20 HLC level 3 Set 254 preset call 5 Through fog level 2 Set 254 preset call 21 Indoor Set 254 preset call 6 Through fog level 3 Set 254 prese...

Page 21: ...on Call 181 Run tour 1 1 5 preset Call 182 Run tour 2 6 15 preset Call 183 Run tour 3 16 30 preset Call 184 Run tour 4 31 50 preset Call 185 Run tour 5 1 30 preset Call 186 Run tour 6 1 40 preset Call 187 Run tour 7 1 60 preset Call 188 Run tour 8 1 80 preset ...

Page 22: ...2 Set 84 Right limit 2 Call 143 A B scan 3 Set 85 Left limit 3 Set 86 Right limit 3 Call 144 A B scan 4 Set 87 Left limit 4 Set 88 Right limit 4 Call 145 A B scan 5 Set 89 Left limit 5 Set 90 Right limit 5 Call 146 A B scan 6 Set 91 Left limit 6 Set 92 Right limit 6 Call 147 A B scan 7 Set 93 Left limit 7 Set 94 Right limit 7 Call 148 A B scan 8 Set 95 Left limit 8 Set 96 Right limit 8 ...

Page 23: ...162 end of recording scanning track 2 Call 153 Run pattern scan 3 Call 163 start recording scanning track 3 Call 164 end of recording scanning track 3 Call 154 Run pattern scan 4 Call 165 start recording scanning track 4 Call 166 end of recording scanning track 4 Call 155 Run pattern scan 5 Call 167 start recording scanning track 5 Call 168 end of recording scanning track 5 Call 156 Run pattern sc...

Page 24: ... track 6 Call 157 Run pattern scan 7 Call 171 start recording scanning track 7 Call 172 end of recording scanning track 7 Call 158 Run pattern scan 8 Call 173 start recording scanning track 8 Call 174 end of recording scanning track 8 ...

Page 25: ...nected wrong or damaged Check RS485 wires connection Self check is abnormal have image but with electrical motor working noise Machine faults Contact supplier for repair Camera is crooked Move and adjust its position Power is not enough Change the power Image is unstable Video wires are poor connection Rule out Power is not enough Change the power Video route has interruption Rule out Intermittent...

Page 26: ...V please only use recommended power supply Please do not force the unit turning around by force whether power is on or off If any of the presets lose their position please call 107 preset position This will reset the dome to normal state Call No 106 clear all Settings to restore factory ...

Page 27: ...0 01Lux Focal range Zoom F 5mm 50mm 10X Digital Reduction 2D Digital noise reduction White balance Automatic Day Night IR CUT S N Ratio 50dB White Balance Indoor Outdoor Auto Manual Dome Features Pan range 360 continuous rotation Tilt range 0 93 auto flip 180 Manual Pan speed 1 200 s Manual Tilt speed 1 120 s Preset speed 400 S Preset Points 255 Pattern Scan 8 groups Guard Tours 8 groups Guard Poi...

Page 28: ... Lightning Protection Transient voltage 10000V Video interface output AHD 1080P Communication mode RS485 Coaxial Cable IR parameters Support ambient light detection IR illumination on 1 25 grades selectable Auto Control IR LED PWM LED Array 42Mil 9pcs IR distance Up to 70 meters Support ambient light detection IR illumination on 1 25 grades selectable ...

Page 29: ... 0mm F1 6 W 2 7 T Day Night AUTO COLOR BW S N Ratio 50dB AGC OFF WDR DWDR White Balance Auto Indoor Outdoor Manual Electronic shutter 1 30s 1 10 000s Dome Features CPU Type 32 bit ARM CPU Luminary Array Φ20 10pcs Night vision distance 150M Lamp control Auto Manual by Zoom Address 0 255 soft address and hard address Pan Range 360 continued rotation Tilt Range 0 90 Auto Flip Manual pan speed 0 240º ...

Page 30: ...adaption Speed slows down automatically when zoom in Intelligent power off real time memory automatic save functions setting automatic wake up tour function Camera Menu operation support the operation of camera set up Manual continued Auto Scan Non limited position of manual continued Auto scan General Work temperature External 35 55 Work Humidity 0 90 Non condensing Power DC12V 10 5A Consumption ...

Page 31: ...warranty excludes products that have been misused including accidental damage and damage caused by normal wear and tear In the unlikely event that you encounter a problem with this product it should be returned to the place of purchase Manufactured exclusively for Xvision UK Unit 2 Valley Point Beddington Farm Road Croydon Surrey CR0 4WP www xvision com www xvision com HD 1080P XHD ...

Reviews: