Xtreme Power 75132 Owner'S Manual And Safety Instructions Download Page 1

ABOVE GROUND POOL SAND FILTER PUMP 2400GPH

SAVE THIS MANUAL: KEEP THIS MANUAL FOR  SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY, 

OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S 

SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH 

AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER).

OWNER’S MANUAL AND SAFETY INSTRUCTIONS

ITEM: 75132

FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT:  (909) 628 0880 MON-FRI 9AM TO 3PM PST

Summary of Contents for 75132

Page 1: ...TING INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 75132 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Page 2: ...l Electrical Code and all applicable local codes and ordinances Improper installation may create an electrical hazard which could result in death or serious injury to pool users installers or others due to electrical shock and may also cause damage to property To reduce the risk of injury do not permit children to use or operate this pump and sand filter DO NOT store chemicals around your pool Che...

Page 3: ... gravity drainage system with ASME ANSI cover s one or more unblock able outlets or B A multiple main drain system without isolation capability with suction outlet covers that meet ASME ANSI A112 19 8 Suction Fittings for Use in Swimming Pools Wading Pools Spas and Hot Tubs and either I A safety vacuum release system SVRS meeting ASME ANSI A112 19 17 Manufactured Safety Vacuum Release Systems SVRS...

Page 4: ...ner Air entering the filter and the valve not clamped correctly can cause the valve to separate which could cause serious personal injury and or property damage Always turn pump off before changing valve positions Changing valve positions while the pump is running can damage the control valve which may cause serious injury or property damage Chemical fumes and or spills can cause serious corrosion...

Page 5: ... filter sand dirt and debris are trapped by the filter bed and filtered out The filter water is returned from the bottom of the filter tank through the multi port and back through the piping system PREPARATION BEFORE INSTALLATION 1 Position the filter as close to the swimming pool spa as possible 2 The filter should be placed on a level concrete slab firm ground or equivalent 3 Position the filter...

Page 6: ...e adapters INSTALLATION NOTES Make sure the filter has worked under work pressure and using a pressure control calve when the system is using a booster pump If the pump position is higher than the water level it requires installing an isolation valve It can stop the water return back when doing the general inspection If the pump position is higher than the water level it requires installation of t...

Page 7: ...rise and flow to diminish When the pressure gauge reading is 8 10 PSI 0 55 0 69 BAR higher than the initial clean pressure you noted it is time to backwash the filter 2 IMPORTANT To prevent unnecessary strain on the piping system and valving always shut off the pump before switching the filter control valve position To prevent damage to the pump and filter and for proper operation of the system cl...

Page 8: ...7 PARTS LIST PARTS LIST ...

Page 9: ...PRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial n...

Reviews: