Xtreme Power 75021 Owner'S Manual And Safety Instructions Download Page 1

1.5HP 220V VARIABLE SPEED IN GROUND POOL PUMP

SAVE THIS MANUAL: KEEP THIS MANUAL FOR  SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY, 

OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S 

SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH 

AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER).

OWNER’S MANUAL AND SAFETY INSTRUCTIONS

ITEM: 75021

FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT:  (909) 628 0880 MON-FRI 9AM TO 3PM PST

Summary of Contents for 75021

Page 1: ...ATING INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 75021 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Page 2: ...esigned This product will be safer and do a better job at the capacity for which it was intended DO NOT use this equipment for a purpose for which it was not intended Keep children and bystanders away from the work area while operating the tool DO NOT allow children to handle the product This pump is intended for use on permanently installed swimming pools and may also be used with hot tubs and sp...

Page 3: ...tangled in suction outlet cover Limb Entrapment A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged broken cracked missing or not securely attached can result in a mechanical bind or swelling of the limb Body Suction Entrapment A pressure applied to a large portion of the body or limbs can result in an entrapment Evisceration Disembowelment A negative p...

Page 4: ...solated from any flammable structures or foreign debris they can cause fires which may cause severe personal injury or death It is also necessary to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk for burns This product should be installed and serviced only by a qualified professional If pump is being pressure tested 40 PSI MAXIMUM be sure pressure has bee...

Page 5: ...RNING Handling the cord on this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling www p65warnings ca gov BENEFITS OF RUNNING AT LOW SPEEDS Save electricity and money Improved filtration the filter can often remove smaller particles when the water moves slower Quiet operation Reduced Tot...

Page 6: ...DIGITAL CONTROL INTERFACE 5 ...

Page 7: ...s enabled Stopping the Pump 1 Press Start Stop to stop the pump When servicing equipment filters heaters chlorinators etc disconnect the communication cable and switch OFF on the circuit breaker to remove power from the pump Adjusting and Saving a Pump Speed 1 While the pump is running press the Up or Down arrow to adjust to desired speed setting 2 Press and hold down a Speed button 1 4 for three ...

Page 8: ...DIGITAL CONTROL INTERFACE OPERATOR CONTROL PANEL PUMP MENU GUIDE 7 ...

Page 9: ...t saving 7 Press Escape to exit SET MINIMUM SPEED RPM The minimum pump speed can be set from 450 RPM to 1700 RPM The default setting is 450 RPM 1 Check that the green power LED is on 2 Press Menu 3 Press Select to select Settings 4 Use the Up or Down arrows to scroll to Min Max 5 Use the Up or Down arrows to scroll to Set Min Spd 6 Press Select to change the setting The cursor will appear in the f...

Page 10: ...cancel any changes press Escape to exit without saving 7 Press Escape to exit SET TEMPERATURE UNIT The default setting is Fahrenheit F The pump can be set to either Celsius C or Fahrenheit F 1 Check that the green power LED is on 2 Press Menu 3 Press Select to select Settings 4 Use the Up or Down arrows to scroll to Device menu item Press Select 5 Use Up or Down arrows to scroll to Temperature Uni...

Page 11: ...eed for that speed button EGG TIMER Menu Setting Egg timer egg timer speed is displayed use the or arrow button to move the cursor and use the arrow button to change the number The range of the speed is 450RPM 3450RPM Press Enter to save settings Press Select egg timer time is displayed use the arrow button to set time The time range is 00 01 19 59 SCHEDULE Program speeds 1 8 start and stop at a s...

Page 12: ... highlighted and scroll to Schedule 5 Press Enter 6 Press Down arrow Set Speed will display and press Select to change Use the Up or Down arrow to adjust speed 7 Press Enter to save the new speed 8 Press the Down arrow again Set Start Time will display Press Select the cursor will highlight the minute column 9 Use the Up or Down arrow to change the time and the Left or Right arrow to move cursor f...

Page 13: ...s Escape to exit without saving 9 Press Escape to exit the menu 12 QUICK CLEAN This feature can be used to increase the pump speed for vacuuming cleaning adding chemicals after a storm for extra skimming capability Press the Quick Clean button LED on and then Start Stop to start When the Quick Clean cycle is over the pump will resume regular schedules and be in Running Schedule mode QUICK CLEAN CO...

Page 14: ...ayers of Teflon tape and re install connector Fittings restrict flow For better efficiency use the fewest possible fittings but at least two suction outlets Avoid fittings that could cause an air trap Pool and spa fittings MUST conform to the International Association of Plumbing and Mechanical Officials IAPMO standards Use a non entrapping suction fitting in pool multiple drains or double suction...

Page 15: ...the motor s voltage phase and cycle and that the wire size is adequate for the KW rating and distance from the power source NOTE All electrical wiring MUST be performed by a licensed electrician and MUST conform to local codes and NEC regulations Use copper conductors only ...

Page 16: ...re that the electrical supply available agrees with the motor s voltage phase and cycle and that the wire size is adequate for the KW rating and distance from the power source Voltage at motor MUST NOT be more than 10 above or below motor name plate rated voltage or motor may overheat causing overload tripping and reduced component life If voltage is less than 90 or more than 110 of rated voltage ...

Page 17: ...WARNING If pump is being pressure tested 40 PSI MAXIMUM be sure pressure has been released using the filter manual air relief valve before removing strainer cover PRIMING THE PUMP CAUTION All suction and discharge valves MUST be OPEN as well as filter air relief valve if available on filter when starting the circulating pump system Failure to do so could result in severe personal injury Release al...

Page 18: ...re beginning shaft seal replacement Exercise extreme care in handling both the rotating and the stationary sections of the two part replacement seal Foreign matter or improper handling will easily scratch the graphite and ceramic sealing surfaces Clean strainer basket regularly DO NOT strike basket to clean Inspect strainer cover gasket regularly and replace as necessary Pumps have self lubricatin...

Page 19: ... of non granulated liquid type soap Do not use petroleum or silicone lubricants as these can contribute to seal leakage 10 Press the new rotating portion of the seal assembly onto the impeller stem with the polished black graphite surface facing away from the impeller 11 Carefully press the stationary ceramic portion of the seal into the recess of the pump housing shroud with the polished flat sur...

Page 20: ...gh to save the current run parameters If power is restored during this process approximately 20 seconds the drive will not restart until completed OVERHEAT If the drive temperature gets above 54 4 C 130 F the pump will slowly reduce speed until the over temperature condition clears OVER CURRENT Indicated that the drive is overloaded or the motor has an electrical problem The drive will restart 20 ...

Page 21: ...TROUBLESHOOTING 20 ...

Page 22: ...TOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no se...

Reviews: