background image

7  

 

UM Termometri serie 7Vio ENG rev.0 14.04.2021

 

 

Instrument Description

 

 

 

Display

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Keypad

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Text String

 

 

Indication of 

instrumental mode

 

 

Battery charge 

 

level 

 

 

Measurement 
unit 

 

 

Type of 

temperature 

probe

 

Stability Indication 

 

 

Error symbol

 

Indication of use of 
the directional keys

 

 

Value 

 

 

On-Off key

 to turn on and 

off the equipment

 

 

ESC key 

to go back at the 

measurement mode

 

 

OK / Setup key

 

to confirm the 

chosen values and enter the

 

Setup from the measurement 
mode

 

DOWN / HOLD key

 to scroll menus and 

values in the Setup. Short press to 
activate the HOLD function.

 

3 seconds pressure to disable HOLD 
function

 

UP / MODE key

 to scroll menus and 

values in the Setup.

 

Short pressure to activate

 

the recording function

 

MAX/MIN, display the recorded MAX and 
MIN values. 

 

3 seconds pressure to exit the MAX/MIN 
recording

 

Unstability 
indication

 

Text string

 

 

Summary of Contents for 7 Vio

Page 1: ...USER MANUAL Temp7 PT100 Temp7 K T Temp7 NTC...

Page 2: ...1 UM Termometri serie 7Vio ENG rev 0 14 04 2021...

Page 3: ...Features 6 Datasheet 6 Instrument Description 7 Display 7 Keypad 7 LED 8 Setup 8 Supplied component 8 Start up 8 Switching On Off 8 Batteries replacement 8 Instrument transportation 9 Keys Function 9...

Page 4: ...serie 7Vio ENG rev 0 14 04 2021 Warranty period and limitations 16 Disposal of electrical devices 16 XS Instruments Via della Meccanica n 25 41012 Carpi MO ITALY Tel 39059 653274 Fax 39059653282 www x...

Page 5: ...ON for a medium risk hazardous situation which could lead to serious injury or death if not avoided ATTENTION for a dangerous situation with reduced risk which can cause material damage data loss or m...

Page 6: ...ime in adverse conditions exposure to direct light heat sources or places saturated by gas or vapours or in environments with conditions different from those mentioned in this manual Device maintenanc...

Page 7: ...curacy 2 C 200 100 C 0 2 C 99 9 199 9 C 2 C 200 999 C 0 1 of the read 0 4 C over 150 C 0 25 of the read 1 C below 150 C 0 2 C System Display High definition colours LCD Backlit Brightness setup Manual...

Page 8: ...uipment ESC key to go back at the measurement mode OK Setup key to confirm the chosen values and enter the Setup from the measurement mode DOWN HOLD key to scroll menus and values in the Setup Short p...

Page 9: ...witching On Off Turn on the system by pressing the button The display initially activates all segments and then appears model and firmware of the instrument settings related to the most important para...

Page 10: ...go back to measurement mode Short MAX MIN memory activation MAX value display and MIN value display It is used to scroll and change the parameters of the Setup menu Long Press 3 sec 3 seconds pressure...

Page 11: ...s and icons Symbols Description Type of probe connected Error in measurement Battery charge indication Measurement stability indicator The bars scroll if the measurement is not stable Press the direct...

Page 12: ...SETUP mode select the parameter you want to edit by using the directional keys and confirming with Within the selected menu move between the different programs using the directional buttons and press...

Page 13: ...e temperature probe connected If menu P 7 2 is accessed without a temperature sensor connected the display will show the error message CONNECT THE PROBE accompanied by the flashing icon Note For the T...

Page 14: ...n three different levels of display brightness LOW low NORMAL medium HIGH high Note Keeping the display bright always adversely affects battery life P9 5 Sleep mode Access this setup menu to select wh...

Page 15: ...ill flash MIN MAX REC Press the key once to see the maximum value reached up to that moment press it another time to see the minimum value reached up to that moment Pressing again will return the inst...

Page 16: ...isolate the water ice mixture from the air as much as possible stir for about 10 minutes in this way a temperature of 0 C is reached If the instrument reads 0 0 C measurement chain accuracy then the i...

Page 17: ...urer will repair or replace defective components This warranty is valid only and exclusively on the electronic parts of the device and does not apply if the product has been damaged used incorrectly e...