Temperature measurement

 

 

 

First start-up

 

 The following parameters must be set when switching on for the first time:

 

Choose the unit of meas. to use

 

°C - °F

 

P 9.1

 

Tutti i modelli

 

Choose the type of probe to be used

 

K / T

 

P 7.1

 

Solo Temp7 K/T

 

Note

: For further settings please refer to the Setup Menu.

 

 

 

 

Measurement

 

Always connect the probe before switching on the instrument.

 

Switch on the instrument with  

 key. After the initial self-diagnosis, the instrument goes directly into 

measurement. Position the probe at the point to be measured and wait for stability.

 

When the reading becomes stable, the icon 

 appears on the display. If this icon does not appear and 

there  are  scrolling  red  bands 

  do  not  consider  the  reading  as  the  final  value.  Always  wait  for 

measurement stability.

 

If  the  temperature  sensor  is  not  connected,  the  following  message  appears  “CONNECT  THE  PROBE”, 

accompanied by the flashing of 

.

 

 

 

MAX/MIN Function

 

During the measurement press the  

  button to start recording the minimum and maximum value.

 

The display will flash "MIN/MAX REC".

 

Press the key once  

  to see the maximum value reached up to that moment, press it another time to 

see the minimum value reached up to that moment. Pressing again will return the instrument to record the 
MAX/MIN value with the flashing letters.

 

To exit MAX/MIN recording, press and hold the button for at least 3 seconds, “MIN/MAX REC" will disappear 
from the display.

 

 

Note

: If auto power off is set, then the instrument will switch off after 20 minutes. If you wish to 

record the minimum and maximum values over a longer period, you must disable auto power off 
P9.9.

 

 

 

HOLD Function

 

During  measurement  press  the 

  button  to  stop  the  reading.  HOLD  appears  on  the  display  and  the 

reading stops. Press again to unlock reading.

 

 

Note

: During MAX/MIN value recording the HOLD function is disabled.

 

 

Note

: during the MAX/MIN function (recording and recalling values) and HOLD the appearance of 

a smile 

 indicates that the measurement at that time is stable. If there are red bands 

 

then the measurement is not stable.

 

 

Note

: during the MAX/MIN (recording and recalling values) and HOLD functions, if the probe is 

disconnected,  the  display  switches  to  measurement  mode  and  the  message  "CONNECT  THE 

PROBE" will appear on the display, accompanied by the flashing of the icon  

 

 

Summary of Contents for 7 Vio

Page 1: ...USER MANUAL Temp7 PT100 Temp7 K T Temp7 NTC...

Page 2: ...1 UM Termometri serie 7Vio ENG rev 0 14 04 2021...

Page 3: ...Features 6 Datasheet 6 Instrument Description 7 Display 7 Keypad 7 LED 8 Setup 8 Supplied component 8 Start up 8 Switching On Off 8 Batteries replacement 8 Instrument transportation 9 Keys Function 9...

Page 4: ...serie 7Vio ENG rev 0 14 04 2021 Warranty period and limitations 16 Disposal of electrical devices 16 XS Instruments Via della Meccanica n 25 41012 Carpi MO ITALY Tel 39059 653274 Fax 39059653282 www x...

Page 5: ...ON for a medium risk hazardous situation which could lead to serious injury or death if not avoided ATTENTION for a dangerous situation with reduced risk which can cause material damage data loss or m...

Page 6: ...ime in adverse conditions exposure to direct light heat sources or places saturated by gas or vapours or in environments with conditions different from those mentioned in this manual Device maintenanc...

Page 7: ...curacy 2 C 200 100 C 0 2 C 99 9 199 9 C 2 C 200 999 C 0 1 of the read 0 4 C over 150 C 0 25 of the read 1 C below 150 C 0 2 C System Display High definition colours LCD Backlit Brightness setup Manual...

Page 8: ...uipment ESC key to go back at the measurement mode OK Setup key to confirm the chosen values and enter the Setup from the measurement mode DOWN HOLD key to scroll menus and values in the Setup Short p...

Page 9: ...witching On Off Turn on the system by pressing the button The display initially activates all segments and then appears model and firmware of the instrument settings related to the most important para...

Page 10: ...go back to measurement mode Short MAX MIN memory activation MAX value display and MIN value display It is used to scroll and change the parameters of the Setup menu Long Press 3 sec 3 seconds pressure...

Page 11: ...s and icons Symbols Description Type of probe connected Error in measurement Battery charge indication Measurement stability indicator The bars scroll if the measurement is not stable Press the direct...

Page 12: ...SETUP mode select the parameter you want to edit by using the directional keys and confirming with Within the selected menu move between the different programs using the directional buttons and press...

Page 13: ...e temperature probe connected If menu P 7 2 is accessed without a temperature sensor connected the display will show the error message CONNECT THE PROBE accompanied by the flashing icon Note For the T...

Page 14: ...n three different levels of display brightness LOW low NORMAL medium HIGH high Note Keeping the display bright always adversely affects battery life P9 5 Sleep mode Access this setup menu to select wh...

Page 15: ...ill flash MIN MAX REC Press the key once to see the maximum value reached up to that moment press it another time to see the minimum value reached up to that moment Pressing again will return the inst...

Page 16: ...isolate the water ice mixture from the air as much as possible stir for about 10 minutes in this way a temperature of 0 C is reached If the instrument reads 0 0 C measurement chain accuracy then the i...

Page 17: ...urer will repair or replace defective components This warranty is valid only and exclusively on the electronic parts of the device and does not apply if the product has been damaged used incorrectly e...

Reviews: