XPR Access WS4 Quick User Manual Download Page 1

4 Door access control unit with web access

EN

QUICK USER GUIDE

WS4 is a 4 door control unit designed to operate with readers with RS485 output. 
There is no need to install any software. There is no need to have a dedicated PC 
either. Everything is available online and the operators just need to register with 
controller’s serial number to start using the software application. 

Capacity: 

 

 

2500 Users

Events:  

 

 

50000 max.

Doors:  

 

 

4 (max. 20 doors in same network)

Readers: 

 

 

4

Door contact inputs: 

 

4

Push button inputs: 

 

4

Auxiliary Inputs: 

 

2 (emergency, vehicle detection) 

Auxiliary Outputs: 

 

2 (alarm, storing alarm status, presence)

Power supply:   

 

120 to 240 V AC, 100 VA-1.52A with fuse (1 A) 

Supply for the readers:   

225 mA each max.

Supply for the locks: 

 

600 mA each max.

Relay characteristics:   

2A/48 VAC/DC#

Processor: 

 

 

ARM A5 - 528 Mhz 

Memory: 

 

 

64 MB Ram DDR2 133 Mhz 

TCP/IP connection:  

 

10/100/1000 Base-T – HTTP or HTTPS

Housing dimensions:   

350 x 250 x 80 mm 

Operating temperature:  

0 °C to +50 °C 

Humidity:  

 

 

0% to 85% (non-condensing) 

Tamper: 

 

 

Yes

Wiegand readers connection:   Yes, via Wiegand to RS485 converter - WS4-CNV

Elevator feature: 

 

Yes, 2 elevators per installation, each - 24 floors

Interlock, Anti pass back, people counter, presence, system logs, reports in CSV

FIRST CONNECTION AND CONFIGURATION

The WS4 does not have default IP address. By default is set to DHCP. There are 2 
methods to connect to and configure WS4 - LAN and Standalone method.

If you can not connect, it is because your network does not recognize the name of the 
WS4 controller. In this case, go to our web site http://www.xprgroup.com/products/ws4/ 
and download the tool called “Device Finder”.
The “Device Finder” will enable you to find out the IP address of the WS4 controller.
Run the “Device Finder” and you will get a list of all the WS4 controllers connected in 
your network, including their IP addresses, just like the picture below.

1. Put the DIP switch 1 in position OFF.
2. Connect a cable from your network to the ethernet connector of Ws4.
3. Open a web browser and enter http://ws4 followed dash and the serial number of 
the WS4 controller

METHOD 1

 

(For use in a home or business LAN network)

Open a browser and type the IP of the WS4 controller and you will be prompted to the 
login page.
User Name: 

admin

Password: 

WS4 

followed by

 Dash 

and the

 Serial Number

 (ex. 

WS4-110034

) just like the 

image below, all in capital letters without space.

WS4-110034

In this configuration, the network’s DHCP server will assign an IP address to your WS4

METHOD 2

 

(For standalone use - without LAN network)

In this configuration, the WS4 will assign an IP address to your PC. The PC must be set to obtain IP 
address automatically.

Serial number

DIP Switch

pos. 1

1

2

3

1. Put the DIP switch 1 in position ON.
2. Connect a cable from your PC directly to the ethernet connector of WS4.
3. Open a web browser and enter the following IP - 192.168.50.100, then put the login 
credentials like explained above

192.168.50.100

FACTORY RESET

DIP Switch 4  allows to log into the system as an administrator if 
login or password is forgotten. Toggle this dip switch 

ON

 for about 

15 seconds

, then back to OFF. The system will then allow, for 5 

minutes, to connect (from the local network only) with the default 
login and password.

DIP Switch 4 allows a complete re-initialization of the system. To 
do this, switch this dip switch 

3 times OFF - ON - OFF

 within 

10 

seconds

.

ON

1

2
3
4

OFF

Factory reset

CHANGE PASSWORD

ON

1

2
3
4

OFF

Change 

password

SOFTWARE SETTINGS

Go to “Doors”, select the reader(fig.2) and then select the type of the reader in the 
field  ”Card”. (fig.3). While off line, red LED blinks fast and buzzer beeps continuously. 
Once communication is established, the red LED and the buzzer stop. Green LED 
starts to blink continuously. If you want to stop the green LED, go to Settings/System 
Options and select for the backlight ON or OFF (not default) fig.4

fig. 1

fig. 3

ADDING READERS

 

Go to 

Users

 (fig.1), select “

New

”(fig.2) and then fill the form (Name, category, card 

number...)(fig.3). 

ADDING USERS

 

fig. 1

fig. 2

WS4 system can manage up to 10 WS4 boards in the same installation (with up to 20 
doors, whether single or double). One WS4 must be master, the others must be 
slaves. The 

master/slave

 selection is made with 

Dip-switch 2

: OFF - Master (factory 

setting), ON - Slave.
Go to “Doors” and click on the link “Add slave”(fig.1). Enter the serial number of the 
WS4 to be added and click Search. If it finds it, the system directly adds this slave 
into the installation and you can configure its doors (fig.2). 
In case of error, a message is displayed in red. 

ADDING SLAVE CONTROLLERS

To add 

2 readers on 1 Door

, select the reader (fig.2) and there, for “Type of Access” 

select “Access with 2 readers” (fig 5). Fill the form for both readers and they will 
merge in one door (fig. 6)

fig. 5

ON

1
2
3

4

OFF

Master/

Slave

Switch

DIP switch 2
OFF

Master

DIP switch 2
ON

Slave 1

DIP switch 2
ON

Slave 9

fig. 1

fig. 2

fig. 4

1

WS4

DESCRIPTION

SPECIFICATIONS

fig. 2

fig. 3

fig. 6

v.a1