4 Door access control unit with web access
EN
QUICK USER GUIDE
WS4 is a 4 door control unit designed to operate with readers with RS485 output.
There is no need to install any software. There is no need to have a dedicated PC
either. Everything is available online and the operators just need to register with
controller’s serial number to start using the software application.
Capacity:
2500 Users
Events:
50000 max.
Doors:
4 (max. 20 doors in same network)
Readers:
4
Door contact inputs:
4
Push button inputs:
4
Auxiliary Inputs:
2 (emergency, vehicle detection)
Auxiliary Outputs:
2 (alarm, storing alarm status, presence)
Power supply:
120 to 240 V AC, 100 VA-1.52A with fuse (1 A)
Supply for the readers:
225 mA each max.
Supply for the locks:
600 mA each max.
Relay characteristics:
2A/48 VAC/DC#
Processor:
ARM A5 - 528 Mhz
Memory:
64 MB Ram DDR2 133 Mhz
TCP/IP connection:
10/100/1000 Base-T – HTTP or HTTPS
Housing dimensions:
350 x 250 x 80 mm
Operating temperature:
0 °C to +50 °C
Humidity:
0% to 85% (non-condensing)
Tamper:
Yes
Wiegand readers connection: Yes, via Wiegand to RS485 converter - WS4-CNV
Elevator feature:
Yes, 2 elevators per installation, each - 24 floors
Interlock, Anti pass back, people counter, presence, system logs, reports in CSV
FIRST CONNECTION AND CONFIGURATION
The WS4 does not have default IP address. By default is set to DHCP. There are 2
methods to connect to and configure WS4 - LAN and Standalone method.
If you can not connect, it is because your network does not recognize the name of the
WS4 controller. In this case, go to our web site http://www.xprgroup.com/products/ws4/
and download the tool called “Device Finder”.
The “Device Finder” will enable you to find out the IP address of the WS4 controller.
Run the “Device Finder” and you will get a list of all the WS4 controllers connected in
your network, including their IP addresses, just like the picture below.
1. Put the DIP switch 1 in position OFF.
2. Connect a cable from your network to the ethernet connector of Ws4.
3. Open a web browser and enter http://ws4 followed dash and the serial number of
the WS4 controller
METHOD 1
(For use in a home or business LAN network)
Open a browser and type the IP of the WS4 controller and you will be prompted to the
login page.
User Name:
admin
Password:
WS4
followed by
Dash
and the
Serial Number
(ex.
WS4-110034
) just like the
image below, all in capital letters without space.
WS4-110034
In this configuration, the network’s DHCP server will assign an IP address to your WS4
METHOD 2
(For standalone use - without LAN network)
In this configuration, the WS4 will assign an IP address to your PC. The PC must be set to obtain IP
address automatically.
Serial number
DIP Switch
pos. 1
1
2
3
1. Put the DIP switch 1 in position ON.
2. Connect a cable from your PC directly to the ethernet connector of WS4.
3. Open a web browser and enter the following IP - 192.168.50.100, then put the login
credentials like explained above
192.168.50.100
FACTORY RESET
DIP Switch 4 allows to log into the system as an administrator if
login or password is forgotten. Toggle this dip switch
ON
for about
15 seconds
, then back to OFF. The system will then allow, for 5
minutes, to connect (from the local network only) with the default
login and password.
DIP Switch 4 allows a complete re-initialization of the system. To
do this, switch this dip switch
3 times OFF - ON - OFF
within
10
seconds
.
ON
1
2
3
4
OFF
Factory reset
CHANGE PASSWORD
ON
1
2
3
4
OFF
Change
password
SOFTWARE SETTINGS
Go to “Doors”, select the reader(fig.2) and then select the type of the reader in the
field ”Card”. (fig.3). While off line, red LED blinks fast and buzzer beeps continuously.
Once communication is established, the red LED and the buzzer stop. Green LED
starts to blink continuously. If you want to stop the green LED, go to Settings/System
Options and select for the backlight ON or OFF (not default) fig.4
fig. 1
fig. 3
ADDING READERS
Go to
Users
(fig.1), select “
New
”(fig.2) and then fill the form (Name, category, card
number...)(fig.3).
ADDING USERS
fig. 1
fig. 2
WS4 system can manage up to 10 WS4 boards in the same installation (with up to 20
doors, whether single or double). One WS4 must be master, the others must be
slaves. The
master/slave
selection is made with
Dip-switch 2
: OFF - Master (factory
setting), ON - Slave.
Go to “Doors” and click on the link “Add slave”(fig.1). Enter the serial number of the
WS4 to be added and click Search. If it finds it, the system directly adds this slave
into the installation and you can configure its doors (fig.2).
In case of error, a message is displayed in red.
ADDING SLAVE CONTROLLERS
To add
2 readers on 1 Door
, select the reader (fig.2) and there, for “Type of Access”
select “Access with 2 readers” (fig 5). Fill the form for both readers and they will
merge in one door (fig. 6)
fig. 5
ON
1
2
3
4
OFF
Master/
Slave
Switch
DIP switch 2
OFF
Master
DIP switch 2
ON
Slave 1
DIP switch 2
ON
Slave 9
fig. 1
fig. 2
fig. 4
1
WS4
DESCRIPTION
SPECIFICATIONS
fig. 2
fig. 3
fig. 6
v.a1