Technical Specification

MODEL NUMBER

X-39AR

X-47ATR

Voltage/Frequency

115 V~60 Hz

Amperage

1.6 A

2.8 A

Motor Power

1/4 HP

1/3 HP

Rated Airflow

2100 CFM

3600 CFM

Speed Control

Variable Speeds

Timer

N/A

3 hours (OFF)

Additional Electrical 

Receptacles (Daisy Chain)

Yes

Cord Length

20 ft. / 6.1 m

Housing

ABS

Unit Dimension

(L) x (W) x (H)

18.6 x 9.4 x 19.2 in. /

47.2 x 23.9 x 48.8 cm

21.9 x 9.8 x 22.5 in. /

55.6 x 24.9 x 57.1 cm

Unit Weight

16.5 lbs. / 7.5 kg

22.2 lbs. / 10.1 kg

Safety Certification

ETL/C-ETL

If your product(s) is not listed above, please visit www.xpower.com for more information.

Summary of Contents for X-47ATR

Page 1: ...Axial Fan Owner s Manual Model X 39AR X 47ATR 115V 60HZ Read and save these instructions before use www xpower com 1 855 855 8868 info xpower com Index NA 1 A25 Edition 2 0 Final ...

Page 2: ...g with wet hands or while standing in water DO NOT operate the appliance in any pooled water DO NOT use the product in areas where gasoline paint or other flammable goods and objects are used or stored DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the appliance and void the warranty DO NOT cover the air inlet or outlet on the appliance DO NOT direct ...

Page 3: ...60HZ Read and save these instructions before use Lea y guarde estas instrucciones antes de usar la unidad Lire et conserver ces instructions avant utilisation www xpower com 1 855 8868 info xpower com Index NA 1 A2 Edition 1 0 Alpha Owner s Manual x 1 Axial Fan Body x 1 Axial Fan x 1 Rack x 1 Rack Handle x 2 Rubber Washer x 2 For model X 39AR only For model X 47ATR only ...

Page 4: ...ir circulation and ventilation in janitorial sanitation jobs water damage restoration and more Parts Description 1 Front Grille Cover 2 Motor 3 Housing 4 Additional Electrical Receptacle 5 Capacitor 6 Housing Handle 7 Switch Plate 8 Rack Handle 9 Rubber Washer 10 Rack 11 Circuit Board 12 Fan 13 Rear End Cover 14 Rear Grille Cover 15 Power Cord 1 2 10 14 13 15 12 3 8 9 8 11 7 6 5 4 ...

Page 5: ...ial fan Fasten the connection with the rack handle For model X 39AR only Switch Plate OFF MAX LOW Variable Speed Switch Turn to OFF position to switch the Axial Fan OFF Turn clock wisely to any position between MAX and LOW to switch the Axial Fan ON You can adjust to any desired speed variably MAX is the highest speed and LOW is the lowest speed ...

Page 6: ...off However the total amperage must be lower than the amperage instructed Different models may have varying instructions If the Axial Fan or the plugged in appliance stops working press the RESET BUTTON to reset the circuit 120 60 0 ON 180 Timer Switch Turn clockwise to set timer for minutes count down to an automatic stop The timer can be set for up to 180 minutes 3 hours When the timer reaches 0...

Page 7: ...Adjust Operation Position The Axial Fan features 360 Rotation Tilt the Axial Fan to desired angle and screw on rack handles to secure the fan s position Use without Rack Uninstall the rack and place the Axial Fan on a level surface For model X 47ATR only ...

Page 8: ...uctions may cause failure of the appliance and void the warranty When not in use unplug and store the appliance in a dry and cool indoor place Make sure it s out of reach of children Before performing any maintenance or cleaning always disconnect the Axial Fan from its power source Use a damp cloth to wipe the surface of the housing Do not clean the unit with water directly Check if the grille cov...

Page 9: ... using this appliance please position the Axial Fan UPRIGHT Fasten the rack handle to lock the position of the Axial Fan Organize the Power Cord Wrap the power cord around the housing Clip the cord to the cord clip on the plug shown above User Maintenance Instructions Continued ...

Page 10: ...ve your problem please contact XPOWER or other parties authorized by XPOWER for further instructions PROBLEM POSSIBLE CAUSE SOLUTION Axial fan does not start No electricity Check for power supply The power cord is not properly plugged in Remove and reconnect the power cord The circuit breaker on the additional electrical receptacle Daisy chain jumps Remove all appliance on the additional electrica...

Page 11: ...ble Speeds Timer N A 3 hours OFF Additional Electrical Receptacles Daisy Chain Yes Cord Length 20 ft 6 1 m Housing ABS Unit Dimension L x W x H 18 6 x 9 4 x 19 2 in 47 2 x 23 9 x 48 8 cm 21 9 x 9 8 x 22 5 in 55 6 x 24 9 x 57 1 cm Unit Weight 16 5 lbs 7 5 kg 22 2 lbs 10 1 kg Safety Certification ETL C ETL If your product s is not listed above please visit www xpower com for more information ...

Page 12: ...ot accordant with product instructions stated in Owner s Manual 3 4 Failure to follow the product instructions or lack of necessary maintenance stated in Owner s Manual Before contacting XPOWER please try one or more of the following 1 Consult this Owner s Manual and follow the instructions of troubleshooting guide 2 Access www xpower com for more advice and information that could be helpful to ad...

Page 13: ...ded by XPOWER with the RMA number on the shipping label or the packaging 3 Include all the original parts and components XPOWER will inspect assess and advise the repairs needed and applicable cost if any For products under warranty we will pay to ship the repaired or replaced product s to you if you use an address within the Contiguous United States Otherwise we will ship the product s to you at ...

Page 14: ...English 14 ...

Page 15: ...English 15 ...

Page 16: ...Read and save these instructions before use www xpower com 1 855 855 8868 info xpower com 240 Clary Avenue San Gabriel CA 91776 USA Index NA 1 A25 Edition 2 0 Final XPOWER Manufacture INC ...