background image

English

Using the fan

DX100BR / DX100BS Only

•  Operate the fan using the on/off switch (not 

supplied). Repeat to switch off. 

DX100BTR / DX100BTS Only

•  Operate the fan using an on/off switch (not 

supplied). Note – the fan may take up to 10 

seconds to turn on once the switch has been 

operated. When the switch is turned off, 

the fan continues to operate for the set time 

delay. To adjust the over-run period, turn the 

control “T” clockwise to increase and anti-

clockwise to decrease – see Figure D1.

DX100BHTR / DX100BHTS Only

•  Automatic mode - The fan automatically 

adjusts to slow changes in natural humidity 

levels without operating the fan. If the humidity 

levels increase at a rate slower than 5% RH 

in 5 minutes, up to the pre-set humidity level, 

the fan will not be triggered by humidity. This 

is to prevent nuisance triggering of the fan. If 

humidity levels increase quicker than 5% RH 

in 5 minutes the fan will operate. When relative 

humidity drops the fan continues to operate for 

the adjustable time delay.

•  External operation - Use the external on/off 

switch. When the fan is switched off, the fan 

continues to operate for the adjustable time 

delay then goes into automatic mode.

DX100BHPTR / DX100BHPTS Only

•  Automatic mode - The fan automatically 

adjusts to slow changes in natural humidity 

levels without operating the fan. If the humidity 

levels increase at a rate slower than 5% RH 

in 5 minutes, up to the pre-set humidity level, 

the fan will not be triggered by humidity. This 

is to prevent nuisance triggering of the fan. If 

humidity levels increase quicker than 5% RH 

in 5 minutes the fan will operate. When relative 

humidity drops the fan continues to operate for 

the adjustable time delay.

•  External operation - Use the external on/off 

switch. When the fan is switched off, the fan 

continues to operate for the adjustable time 

delay then goes into automatic mode.

•  Pull Cord operation – Use the integral pull 

cord switch. When the fan is switched off, the 

fan continues to operate for the adjustable 

time delay then goes into automatic mode.

DX100BPR / DX100BPS Only

•  Operate the fan by pulling and releasing the 

cord. Repeat to switch off.

All Fans

Re-fit the front cover by hooking in the top first, 

and then swing the cover down to clip into place. 

Cleaning 

(recommended once a month)

1. Before cleaning, isolate the fan completely 

from the mains supply.

2. Remove the front cover by depressing the 

latch on the underside of the cover and 

pulling off the front cover from the bottom.

3. To clean the front cover, either wipe it with 

a damp, lint free cloth or wash it with warm 

soapy water. Thoroughly dry the front cover 

and refit.

4. Do not immerse the fan in water or other 

liquids to clean any other parts of the fan.

5. Do not use strong detergents, solvents or 

chemical cleaners

6. Allow fan to dry thoroughly before use.

7. Apart from cleaning, no other maintenance is 

required.

Disposal

This product should not be disposed 

of with household waste.
Please recycle where facilities exist.
Check with your local authority for 

recycling advice.

Guarantee

UK only

We, Redring Xpelair Group Limited, provide a 

guarantee against faulty parts and manufacture 

for a period of 2 years from the date of 

purchase. In the unlikely event of a product 

breakdown during the guarantee period the 

product should be returned to the place of 

purchase or to Redring Xpelair Group Limited. 
Exclusions

•  This guarantee does not cover compensation 

for the loss of the product or consequential 

loss of any kind.

•  Damage or defects to the product arising from 

incorrect installation or lack of maintenance.

•  Transportation costs.
This guarantee does not affect your 
statutory rights

Summary of Contents for DX100B

Page 1: ...017AW DX100BTR 92998AW DX100BTS 93018AW DX100BHTR 92999AW DX100BHTS 93019AW DX100BHPTR 93000AW DX100BHPTS 93020AW DX100BPR 93001AW DX100BPS 93002AW Xpelair Simply Silent DX100B Installation and Mainte...

Page 2: ...e electrical connections or carry out any maintenance or cleaning Please leave this leaflet with the fan for the benefit of the user Installation and Maintenance Instructions English Standard Timer Hu...

Page 3: ...by the integral humidity sensor by using an external on off switch not supplied or by using the integral pull cord switch In automatic mode The built in timer automatically operates the fan for the pr...

Page 4: ...n timer setting Fan switches on at lower level of condensation anti clockwise MORE SENTITIVE RH 50 Fan runs on for a shorter time when the external switch is turned off Fan does not switch on until hi...

Page 5: ...USTOMER CONNECTION TERMINAL DETAIL C SCALE 2 000 OVER RUN TIMER DETAIL B SCALE 2 000 SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING HIGH SPEED LOW SPEED SEE DETAIL A CUSTOMER CONNECTION TERMINAL SE...

Page 6: ...SEE DETAIL E CUSTOMER CONNECTION TERMINAL DETAIL F SCALE 2 000 SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING HIGH SPEED LOW SPEED DETAIL D SCALE 2 000 OVER RUN TIMER HUMIDISTAT DETAIL E SCALE 2 0...

Page 7: ...trical supply at this stage 6 Install the isolating switch and on off switch if required 7 Make all connections within the isolating switch and the on off switch if required Wet Rooms On Off switch mu...

Page 8: ...increase and anti clockwise to decrease see Figure D1 DX100BHTR DX100BHTS DX100BHPTR DX100BHPTS only see figures C and D The pre set humidity operation is factory set at approximately 75 Relative Hum...

Page 9: ...on off switch When the fan is switched off the fan continues to operate for the adjustable time delay then goes into automatic mode Pull Cord operation Use the integral pull cord switch When the fan i...

Page 10: ...for details By telephone on Techline 44 0 844 372 7766 By fax on Techfax 44 0 844 372 7767 At the address below Head Office UK Sales Office and Spares Redring Xpelair Group Ltd Newcombe House Newcombe...

Page 11: ...Office UK Sales Office and Spares Redring Xpelair Group Ltd Newcombe House Newcombe Way Orton Southgate Peterborough PE2 6SE England Telephone 44 0 844 372 7761 www xpelair co uk www xpelair co uk int...

Reviews: