XT-20P 

Ceiling SIP IP Speaker 

 

 

 

 

 

 

 

Summary of Contents for XT-20P

Page 1: ...XT 20P Ceiling SIP IP Speaker...

Page 2: ...g 6 User define Terminal Parameters 6 Login Webpage 6 Running Status 7 Network Parameter 8 Server Parameter 9 Audio Parameter 11 Alarm options 12 Multicast 12 System Settings 13 Language Settings 13 T...

Page 3: ...ontact with supplier It may cause fires or electric shock if it s still using it When the device with smoking or strange flavor The device internal is invaded by water or other things Device fall off...

Page 4: ...speaker Timing broadcast it will upload all the audio source need to be daily broadcast on server and make broadcasting schedule Ceiling speakers can be configured by the server s scheduled task to ac...

Page 5: ...ck the fittings before the installation if any missing please contact the distributor 1 IP ceiling speaker 1 pcs 2 Waterproof connector 1 pcs 3 Wiring terminal 3 81 2P 1 pcs 4 Wiring terminal 3 81 4P...

Page 6: ...odify all the parameters according to the live environment After finishing click save User define Terminal Parameters Login Webpage 1 Please input the IP address of IP ceiling speaker to the address c...

Page 7: ...age Note If the relevant parameter modification in the web page does not take effect after saving please clear the cache and set them again Running Status When login to the web page click Running Stat...

Page 8: ...ters are as follows Terminal IP The IP address of the device the factory default IP is 192 168 1 101 which cannot be duplicated with other terminals Subnet Mask The subnet mask of the LAN network Gate...

Page 9: ...for terminal to login to SIP server default is 1234 Local port Configure the local port according to the actual situation the default is 5060 Audio port Configure the audio port according to the actua...

Page 10: ...local port according to the actual situation the default is 5060 Primary Server IP port IP address of the NAS server that the terminal logs in to Please enter the correct IP address or domain name of...

Page 11: ...se of the surrounding environment is less than the reference noise and the range of less than the set noise detection calibration value the real time volume level of the equipment broadcast will be re...

Page 12: ...ast function Set whether to enable multicast function or not In the case where there are multiple servers in the LAN different servers must fill in different addresses and port numbers when they initi...

Page 13: ...this button will reboot the device Default Click this button and all parameters of the device will be restored to factory Settings please use with caution Language Settings You can change the languag...

Page 14: ...Time To Restart After this function is enabled you can set the time for restarting the device every day The default value is disabled...

Page 15: ...TP Set whether to enable FTP remote file transfer function The default value is disable TELNET Set whether to enable the TELNET remote login function The default value is disable User Management You c...

Page 16: ...the manufacturer and click Start upload to start the upgrade Note Do not power off during the upgrade process otherwise the upgrade may fail and the device fails Finally click reboot and back to norm...

Page 17: ...rd connected normal If the network port green light is not on it means the network hard connected problem please check the terminal network cable and switcher whether they work normal damaged and disc...

Page 18: ...n and shall not spread in any forms According to the legal provisions copy including translate to other language or switch to other format Mentioned document spreading in network media XonTel allow do...