background image

RANGE HOOD - User instructions

HOTTE DE CUISINE - Notice d’utilisation

CAMPANA EXTRACTORA - Manual de utilización

USA

F

E

XOBI36S

XOBI42S

NEED HELP?

Call our ventilation experts toll free al 800-966-8300

AVEZ-VOUS BESOIN D’AIDE ?

Contactez nos experts au numéro gratuit 800-966-8300

¿NECESITA AYUDA?

Póngase en contacto con nuestros expertos a través del número gratis 800-966-8300

Summary of Contents for XOBI36S

Page 1: ...A Manual de utilización USA F E XOBI36S XOBI42S NEED HELP Call our ventilation experts toll free al 800 966 8300 AVEZ VOUS BESOIN D AIDE Contactez nos experts au numéro gratuit 800 966 8300 NECESITA AYUDA Póngase en contacto con nuestros expertos a través del número gratis 800 966 8300 ...

Page 2: ...iginal purchaser for products purchased for ordinary home use in North America Should you require service for your XO product call a product service specialist at 800 966 8300 Improper Installation Service trips to the home to teach you how to use the product Resetting circuit breakers Damage caused after delivery EXPECT MORE FROM XO When buying any XO appliance you can be confident you have purch...

Page 3: ...s and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Please read specification label on product for further information and requirements WARNING TO REDUCETHE RISK OF FIRE ELECTRIC SHOCK OR INJURYTO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you h...

Page 4: ...inguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit aBased on kitchen firesafety tips published by NFPA Proper maintenance of the Range Hood will assure proper performance of the unit INSTALLATION I...

Page 5: ...s after a prolonged use of the appliance C No food must be cooked flambè underneath the hood D The use of an unprotected flame is dangerous for the filters and could cause fires E Watch constantly the fried food in order to avoid the cooking oil flares up F Before performing any mainteinance operation disconnect the hood from the elec trical service The manufacturers will not to accept any respons...

Page 6: ...erruption of such naturally vented systems follow the heating equipment manu facturer s guidelines and safety standards such as those published by NFPA Duct Piece Dimensions Equivalent Number Length Quantity Used Total Equivalent Length Round straight 1 ft per foot lenhgth 3 1 4 x 10 straight 1 ft per foot lenhgth 90 elbow 12 ft 45 elbow 7 ft 3 1 4 x 10 3 1 4 x 12 90 elbow 14 ft 10 ft 3 1 4 x 10 3...

Page 7: ...pe or Duct Tape INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 Decide where the ductwork will run between the hood and the outside 2 A straight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible 4 Install a roof or wall cap Connect 6 round metal...

Page 8: ... 8 Hood Specifications Front of hood Side of hood Top of hood Mounting height and clearance Product dimensions and clearance XOBI36S XOBI42S ...

Page 9: ...ockingof the upper part ofstructure B Take the lower part of the telescopic structure C and insert it into the upper structure B Fig 4 Adjust the height and block it using the 8 screws G that are supplied Fig 5 Fix the flexible pipe to the prepared air evacuation hole Fig 6 Taketheupperchimneypieceandfixitto the structure using the 2 screws A Fig 7 Join the lower chimney piece with the up per one ...

Page 10: ... 10 Fig 4 Fig 5 Fig 3 ...

Page 11: ... 11 Fig 6 Fig 7 Fig 9 Fig 8 ...

Page 12: ...not the case install a support structure made up from 2 by 4 inch cross members in correspondence with the screw anchorage points IMPORTANT Therangehoodmustbesecuredtowallstudsorusedrywallanchors capable of supporting 75 lbs Fig 11 Fig 10 ...

Page 13: ...st be 2 wire with ground If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Route house wiring as close to the installation location as possible in the ceiling or back wall Refer to Wiring Locations on page 14 Connect the hood wiring to the house wiring in accordance with local codes Grounding instructions The grounding conductor must be con...

Page 14: ... box cover 3 Secure the power supply conduit to the cover 4 Connect the wires of the hood to those of the power supply as described Fig 12B BLACK L line WHITE N neutral GREEN YELLOW G ground A double pole switch properly rated must be installed to provide the range hood power supply disconnection Connect the electrical conduit to the Field Wiring Compartment using listed conduit fittings Fig 12 Fi...

Page 15: ...of 27 from an electric cooker stove or 32 from gas or combined cooker stoves If a connection ductwork composed of two parts is used the upper part must be placed outside the lower part Do not connect the range hood exhaust duct air to the same duct air used to exhaust hot air or fumes from other appliances other than electrical Before proceeding with the assembly operations remove the anti grease ...

Page 16: ... supply the electrical box must be secured in place as indicated in Fig 14 Before installing the appliance fix the electrical box as indicated in Fig 14 Lift the electrical plant box Fig 14A Remove the 3 fixed screws Fig 14B Position the electrical box so it is in line with the holes of the previously removed screws Fig 14C and tighten Fig 14 ...

Page 17: ... Itmaybenecessary to cut the deviator to fit the width of the chimney as shown in picture 3 2 A sharp blade or Hacksaw is recommended to trim the plastic Carbon filter kit XORFK04 The kit includes an air diverter A 1 screw and 2 round filters C Fig 2 To remove the two screws E to take down the lower chimeny F ...

Page 18: ...pe Not Included on the flange of connection 3 Fig 6 Remove adhesive tape 2 and rest the lower chimney piece above the cooker hood 6 Round Flexible Metal Duct Pipe Not Included 6 Round Flexible Metal Duct Pipe Not Included Fig 3 TofixtheairdiverterAonthesupport s bracket using the screw B as it is shown in the figure Once that the air diverter A has been fixed it is necessary to connect the flexibl...

Page 19: ...ulling the lever 1 out and pushing downwards 2 Fig 8 The filters C must be applied to the suction unit inside the hood centering them inside of it and turning them 90 until they snap into place Fig 9 Put the aluminum panels back in place Fig 7 ...

Page 20: ...d the LED of key F remains switched on with a fixed light until the motor starts up again at the first speed after fifty minutes and keys F and C start to flash again for ten minutes and so on By pressing any key for the exclusion of the hood light the hood will return immediately to its normal functioning e g if key D is pressed the clean air function is deactivated and the motor moves to the 2nd...

Page 21: ... which is released back into the room The filters are not washable or re usable and must be replaced at least once every four months The active carbon filter saturation level depends on the frequency with which the appliance is used the type of cooking performed and the regularity with which the anti grease filters are cleaned Cleanthecookerhoodfrequently bothinsideandoutside usingaclothwhichhasbe...

Page 22: ...ce causing rust DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals with may be harmful Rinse with water after exposure and wipe dry with a clean cloth Painted surfaces should be cleaned with warm water and mild detergent only ...

Page 23: ... In case of necessity it can be replaced only by spe cialized personnel Replacing halogen light bulbs To replace the halogen lamps B from the inside of the cooker hood press downwards with two fingers as shown in Fig 15 Replace the bulbs with new ones of the same type Fig 15 ...

Page 24: ... 24 XOBI36S XOBI42S ...

Page 25: ... 25 OPTIONS AND ACCESSORIES Model XORFK04 Ductless Recirculating Filter Kit Model XOEDCBI Duct Cover Extension This accessory is available for installation with ceiling heights above 9 ft to 10 ft ...

Page 26: ...nstallation hardware Locate the hardware package packed with the hood and check contents TYPE DESCRIPTION N A 1 8 x 6 16 18 B 3 16 x 5 16 14 C 1 8 x 6 16 2 Aluminum filters 2 piece decorative duct cover dimension shown for reference only ...

Page 27: ...ardChimneyfitsceilingsupto9fttall optional chimney extension for ceilings up to 10 ft Mounting Height from cooking surface 27 32 Duct Options and Electrical Requirements 6 inch duct required Ductless Option for applications where no ducting in available AC 120v 60Hz 4 35amp Options Optionalductcoverextensionisavailableforceiling heights up to 10 ft tall Model XOEDCBI Optional recirculating kit if ...

Reviews: