Xo 4 Manual Download Page 1

 

 

 
 

 
 
 

 

 

 
 
 

 
 

 
 
 

 
 

 
 
 

 
 

 

 

 

 
 

 
 
 

 
 

YB-904 

Version 1.10 

 

 

XO

®

 4      

RETROFIT OF XO WATERCLEAN SYSTEM 

XO CARE A/S 
Usserød Mølle 

Håndværkersvinget 6  +45 70 20 55 11 
DK 2970 Hørsholm 

[email protected] 

Denmark   

www.xo-care.com 

 

Summary of Contents for 4

Page 1: ...YB 904 Version 1 10 XO 4 RETROFIT OF XO WATERCLEAN SYSTEM XO CARE A S Usser d M lle H ndv rkersvinget 6 45 70 20 55 11 DK 2970 H rsholm info xo care com Denmark www xo care com...

Page 2: ...XO CARE A S YB 904 Ver 1 10 Page 2 of 14...

Page 3: ...and handling electronics in the XO 4 Unit always use ESD antistatic wristband UC 600 Tools needed Torx20 screwdriver Torx10 screwdriver Nipper Hose cutter Approx 15 cable ties Complete kit XO 450 AP 9...

Page 4: ...4 of 14 Dismount the cover 1 from the service door On the left side of the Unit 4 Torx 20 screws The bottle holder system Fit the bottle holder system where you previously have removed the cover by u...

Page 5: ...ARE A S YB 904 Ver 1 10 Page 5 of 14 The liquid motor pump for Water Clean Fit the pump in the farthest left position of the XO 4 Unit by using the included two Torx 20 screws The water tank with fitt...

Page 6: ...RE A S YB 904 Ver 1 10 Page 6 of 14 Mounting holes of the water tank Fit the water tank and the white mixing cup in the pre drilled holes in the mounting plate using four Torx 20 screws 3 way air valv...

Page 7: ...10 Page 7 of 14 Fit the 3 way valve V30 in the holes in the mounting plate using the included two Torx 10 screws The 2 way water valve V27 Fit the 2 way water valve V27 in the left position using the...

Page 8: ...e on top of backflow prevention Measure and cut 4 pieces of 4 mm blue tube for the 3 way valve V30 7cm Air pressure from valve V30 to top of backflow prevention 11 5cm Pressure relief from water tank...

Page 9: ...B 904 Ver 1 10 Page 9 of 14 Make sure to fit the non return valve with the arrow pointing upwards Remove the 4mm clear water tube connecting the outlet of the pressure regulator and the regulator of t...

Page 10: ...lear 4 mm tube and connect it between the outlet of the water pressure regulator and the inlet of the water valve V27 Connect the supplied 4mm spiral tube between the outlet of the 2 way water valve V...

Page 11: ...CARE A S YB 904 Ver 1 10 Page 11 of 14 Connect the water outlet from the pressure tank to the T fitting next to the cup filler regulator Connect cable CA 033 plug J37 to connector J37 on the Backplan...

Page 12: ...r end of the cable CA 033 plug V31 to the liquid pump V31 Red wire connects to the wire with the label Connect CA 033 plug S5B to connector J1 on the cup level sensor Connect CA 033 plug s14 to the co...

Page 13: ...B 904 Ver 1 10 Page 13 of 14 Connect cable CA 007 plug J5 to connector J5 on the backplane Connect cable CA 007 plug S5 to connector J2 on the cup level sensor Connect cable CA 007 plug V30 to the 3 w...

Page 14: ...14 Connect cable CA 007 plug V27 to the 2 way valve V27 Fit the overflow tube on the side of the mixing cup and put the other end down towards the water reservoir Test the newly installed equipment an...

Reviews: