XT6264 User Guide
P a g e
11 | 14
CONFIDENTIAL AND PROPRIETARY
Disclosure, storage and use subject to non-disclosure agreement
3.2
I
NSTALL
M
ODE
3.2.1
Entering Install Mode
The device must be active, i.e., either on battery hold off period or external power. This is not applicable
during battery profile wakes (periodic, listen, motion start/stop).
Press and hold the button until the blue LED is blinking; release the button. The device will reboot into
install mode indicated by the fast blinking green LED.
3.2.2
Install Mode Operation and Status
Install mode is a special test mode which does not provide normal operations. Test in progress is
indicated by a fast blinking green LED. At the end of the Install mode test, the following test result status
would be displayed through solid LED indication. LED1 is the left most LED and LED2 is next to LED1 and
so on.
AC Power Connection
•
Green LED1: AC power detected
•
Red LED1: Failed AC power detection
RS232 physical connection
•
Green LED2: Physical RS232 detected
•
Red LED2: Failed RS232 detection
Reefer Communication
•
Green LED3: Successful communication with controller
•
Red LED3: Failed communication with controller
3.2.3
Exiting Install Mode
•
Push the button and hold for approximately five seconds any time after install mode status
indication.
•
OR, timeout for fifteen minutes from the start of LED status indication.
NOTE: either of the above will cause a reboot of the device to the normal operation mode.