Page 1: ...nd Solenoid Control P 1CS R Chrome Round Solenoid Control Dual Channel Svstem P 2BS R Black Square Solenoid Control Owner s Manual lnstallation lnstructions Read and comply with all instructions warnings and limitations before installing servicing or removing this device 1 Part Number 18143 B 01 12712017 ...

Page 2: ...lnstalling the Display Unit p1BR S01 D P1CR SO1 D p2BS_SO1D Routing Sensor Cable s FS X01 CABLE XX lnstalling Propane Fume Sensor s FS TO1 Electrical Connections P j BR SO1 D p1CR SO j D p2BS SO1D Testing the System Operation Testing the Propane Fume Sensors Maintenance ln the Event of an Alarm Repairing Xintex Propane Detection Components Returning Xintex Propane Detection Components L Year Limit...

Page 3: ...ol theflowofCNG LPGtoyourappliances Thesystemusesasensor locatedinaplaceof interest and a central display unitthat notifies you ofthe state ofthe system Specification Svstem Specifi cations P 1BS R P 1CS R Operating Voltage 9 30 VDC Nominal Current Draw 55mA 12 VDC Maximum Current Draw 725mA 9 VDC Operating Temperature 40 F 40 C to 185 F 85 C Alarm Horn 68dB Svstem Specifi cations P 2BS R Operatin...

Page 4: ...LEL Lower Explosive Limit which is considered an a larm The alarm horn will sound when the Red LED is illuminated The alarm horn will actuate Solenoid Valve will close and the Solenoid Valve status LED will deactivate when the Red LED is illuminated Wheneverthe Solenoid Valve status LED is illuminated the Solenoid Valve is open PlBR SO D P1CR SO1 D P2BS SO1 D The alarm status will continue as long...

Page 5: ...xll r xll r ull o JH e 5 U HC dnd oll ll tzrA r o HA l Id mA H og C o6 E _ EIE E E E E IuN O 8E 3s H 5 T E 3 i 3 e 2 Qr t u t S r lo ll f n n rhl t_ 1 I il llx l ll J ll co _H_ 3 tl a ll o II T ll r o11 rll n 5H jm c o E oo 6 c J 9 bo c o I o J U E E 5 o 9 bo c E I I o J J U C 5 o I z J l co 3 o B o d I o U E oo dd oo d E co J dd Ld 5 Part Number L8L43 B 0L12712017 ...

Page 6: ... Display Unit using the attached quick disconnect connectors Take care not to pinch break or cut the sensor cable or put too much stress on the connectors while routing the cable secure the sensor Cable with the appropriate hardware for the application DO NOT CUT EXTENSION CABLE FOR ANY PURPOSE DOING SO VOIDS THE PRODUCTS WARRANTY LONGER CABLES ARE AVAILABLE FROM 20 FTTO 1OO FT lnstalline Propane ...

Page 7: ...w Fault LED should illuminate lf the Yellow LED does not illuminate remove Display Unit and return direct to manufacturer following the instructions at the back of this manual To test the Solenoid Control function check that the flame of your appliance extinguishes when the Solenoid Control function is turned OFF Testing the Propane Fume Sensors DO NOT USE A PROPANE SOAKED RAG OR A PARTIALLY FULL ...

Page 8: ...omponents must be returned to the factory for any repairs Returning Xintex Propane Detection Components No product may be returned for credit or repair without a written Returned Material Authorization RMA form Purchaser must call or email Fireboy Xintex 516 735 9380 or fireboy fireboy xintex com for a RMA lf due to extenuating circumstances a product is to be returned afterapproval it must be rec...

Page 9: ...x lnc does not assume the costs of removal and or installation of the product or any other incidental costs of removal and or installation ofthe product or any other incidental costs which mayariseasaresult ofanydefectinmaterial orworkmanship and e upondiscoveryof defect Buyer shall immediately cease use of and notify Fireboy Xintex lnc Any warranty implied by law including warranties of merchanta...