background image

Part Number

 

18143,

 

E, 01/28/2020 

 
 
 
 

 
 

Propane Fume Detection System 

With Solenoid Valve Control 

 
 
 
 

Single Channel Systems 

P-1BS-R (Black, Round, Solenoid Control, 12V Solenoid) 

P-1BS-24-R (Black, Round, Solenoid Control, 24V Solenoid) 

P-1CS-R (Chrome, Round, Solenoid Control, 12V Solenoid) 

P-1CS-24-R (Chrome, Round, Solenoid Control, 24V Solenoid) 

 

Dual Channel System 

P-2BS-R (Black, Square, Solenoid Control, 12V Solenoid) 

P-2BS-24-R (Black, Square, Solenoid Control, 24V Solenoid) 

 
 
 
 

Owner’s Manual

 

Installation Instructions 

 
 
 

 

Read and comply with all instructions, warnings and limitations before 

installing, servicing or removing this device. 

 
 

Summary of Contents for P-1BS-R

Page 1: ...ol 24V Solenoid P 1CS R Chrome Round Solenoid Control 12V Solenoid P 1CS 24 R Chrome Round Solenoid Control 24V Solenoid Dual Channel System P 2BS R Black Square Solenoid Control 12V Solenoid P 2BS 24...

Page 2: ...talling the Display Unit P1BR S01 D P1CR S01 D P2BS S01D 6 Installing the Solenoid Valve for LPG Applications 6 Routing Sensor Cable s FS X01 CABLE XX 6 Installing Propane Fume Sensor s FS T01 7 Elect...

Page 3: ...e system Specification System Specifications P 1BS R P 1CS R Operating Voltage 9 18V DC Nominal Current Draw 55mA 12V DC Maximum Current Draw 725mA 9V DC Operating Temperature 40 F 40 C to 185 F 85 C...

Page 4: ...e bottom indicates a fume buildup of 20 of the LEL Lower Explosive Limit which is considered an alarm The alarm horn will sound when the Red LED is illuminated The alarm horn will actuate Solenoid Val...

Page 5: ...er 2A May be obtained Display Unit 2A fuse recommended Solenoid Valve YELLOW Switching Ground 2A Fuse Included FS X01 CABLE XX FS T01 FS X01 CABLE XX FS T01 P2BS S01 D RED Power 1 0 Amp Fuse from Circ...

Page 6: ...ctical The tank itself should be mounted outside the cabin or crew quarters to avoid the possibility of gas accumulation due to a leak NOTE TIGHTEN TO 12 13 FT LBS DO NOT OVER TIGHTEN NOTE ALL PIPING...

Page 7: ...used Yellow 16 GA wire is provided for connecting the Display Unit to the Solenoid Valve Connect the Yellow wire to the Solenoid Valve Connect the positive voltage to the Solenoid Valve NOTE UNITS MAN...

Page 8: ...ngers and crew exit the passenger compartment and vessel if possible Ventilate the space being monitored Carefully check all fuel lines and other potential sources of propane fume leaks If leaks are i...

Page 9: ...ent of Fireboy Xintex LLC does not assume the costs of removal and or installation of the product or any other incidental costs of removal and or installation of the product or any other incidental co...