Xinje XP-18 Series Operating Manual Download Page 1

XINJE 

XP/XMP-18 

series

Integral industrial controller 

Operating manual

 

Summary of Contents for XP-18 Series

Page 1: ...XINJE XP XMP 18 series Integral industrial controller Operating manual...

Page 2: ...r i e s O p e r a t i n gm a n u a l V 1 0 Catalog Preface Safety Notes Summarization Input output specification and exterior layout PLC Function and Application HMI Function and Application Extensio...

Page 3: ...k normally in the condition of be transported kept and installed correctly also please operate and maintain them according to the recommendation Xinje Electronic Co Ltd Copyright reserved Without exac...

Page 4: ...cs and circuit 19 2 3 Transistor output specs and circuit 21 3 PLC FUNCTION AND APPLICATION 23 3 1 PLC instruction 23 3 2 soft component range 24 3 3 Set up a project 28 3 4 communication function 31...

Page 5: ...product characteristics spec explanation using method etc n This manual contains product summarization exterior layout PLC program and exterior extension Summarization introduce the product characteri...

Page 6: ...n with pen screwdriver or other sharp tools it may cause screen break or error For installing the product tighten the screws to avoid loosing Transport install store assemble and maintain the product...

Page 7: ...can extend BD board to realize analog quantity in out control Easy edit of the HMI picture rich function u LCD display 192 64 pixel 3 7 inch LCD useful life can reach 0 5 million hours u 26 function k...

Page 8: ...ies 3 In out points 18 Input 10 points output 8 points 4 Output Type R Relay output T Transistor output RT Relay Transistor output Notice XMP series exclude XMP2 32 series products in this manual Abou...

Page 9: ...V between signal and ground Operating temperature 0 50 Storage temperature 10 60 Environment temperature 20 85 No dew Endurable quiver 10 25Hz X Y Z direction for 30 minutes Anti jamming Voltage Noise...

Page 10: ...Set time 0 01 327 67 seconds 1mS timer Set time 0 001 32 767 seconds Points 48 640 640 Counter C Specs 16 bits counter set value K0 32767 32 bits counter set value 2147483648 2147483647 Data Register...

Page 11: ...nal interrupt Setting of time scan space 0 99mS Password protection 6 bits ASCII Self diagnose function Power on self diagnose Monitor timer grammar check Note The user program capacity is referred to...

Page 12: ...elow Pin Function Pin2 RXD Pin3 TXD Pin5 GND Pin7 RTS Xinje provides special program cable to download the PLC program or HMI program You also can make the cable by yourself Please see the pin connect...

Page 13: ...7 CTS Communication port A and B is a RS 485 com port This port is used to connect other devices Please refer to paragraph 3 4 for details 1 4 Outline dimension Unit mm Communication port Outline dim...

Page 14: ...16 Unit mm Installation dimension 1 6 4 1 1 3...

Page 15: ...d be NPN open collector D Cp o w e r D C 2 4 V p o w e rs u p p l y R 3 R 4 R 2 R 1 X 7 X 0 C O M 5 V R 5 R 6 L E D I 7 m A s e n s o r s u p p l y Input signal s voltage DC24V 10 Input signal s curre...

Page 16: ...ler the second loop has C R filter which can prevent wrong action caused by industry noise or input points oscillation As the result there will be a response delay for 10ms to the input points There i...

Page 17: ...roduces close sound when it is on l Response time The response time is about 10ms transferring the ON or OFF signal from relay output coil to the output connection l Output current Output current is 3...

Page 18: ...e product will be broken l For DC inductor load please parallel connect with commutate diode If not connect with the commutate diode the point s life will be decreased greatly Please choose the commut...

Page 19: ...Maximum current 50mA Maximum pulse frequency 200KHZ Type RT output T output Transistor output point Y2 Y3 Y2 Y7 Power supply Below DC5 30V Circuit insulation Optical coupling insulation Resistor load...

Page 20: ...stor is ON l Response time From optical coupler driving or cut to transistor ON or OFF the time is below 0 2ms l Output current The current is 0 4A per point But due to restriction of temperature goin...

Page 21: ...ed instructions and special function instructions Please refer to XC Series PLC Manual paragraph 4 5 6 XP2 XMP2 and XP3 XMP3 have special function instructions please refer to XC Series PLC Operating...

Page 22: ...X5 I0100 I0101 M8051 CHL3 X10 I0200 I0201 M8052 4 Frequency measurement The point is X1 X11 X12 5 Pulse width modulation The point is Y0 Y1 u T type Y0 Y1 available u RT type Y0 Y1 available u R type...

Page 23: ...10ms accumulation T400 T403 1ms not accumulation T Timer T500 T503 1ms accumulation 80 C0 C23 16 bits plus counter C300 C315 32bits plus minus counter C600 C603 vacant C620 C621 vacant C Counter C630...

Page 24: ...0 C598 32 bits forth back counter C600 C619 one phase high speed counter C620 C629 Pulse direction high speed counter C Counter C630 C639 AB phase high speed counter 640 D0 D999 D4000 D4999 D0 D3999 D...

Page 25: ...31 S FD8206 First address of the power failure memory area of S 512 S0 S31 XP2 XMP2 Soft component Area Function Default value Power failure memory area D FD8202 First address of the power failure mem...

Page 26: ...D0 ED16383 NOTE Users can set the power failure memory area but the area can not over the soft component area 3 3 Set up a project The PLC program editing software is the same as Xinje XC series Softw...

Page 27: ...pile the program For program compiling and software operating please refer to XC Series Edit Tool XCP Pro User Manual XP1 XMP1series choose XP1 18 XMP1 18 XP2 XMP2 series choose XP2 18 XMP2 18 XP3 XMP...

Page 28: ...to choose these parameters automatically When below window shows connect to PLC succeeded it means the connecting is successful Click OK to continue If the connecting is not successful the window wil...

Page 29: ...tion protocol The instructions please refer to XC Series PLC Operating Manual paragraph 6 4 1 and 6 4 2 XP XMP series product have program port DB9 pins port and RS 485 com port A B point Program port...

Page 30: ...ps Data bit 8 or 7 bits Stop bit 2 or 1 bits Check Even odd no check The defaulted parameters of the port Station number is 1 baud rate is 19200bps 8 data bit 1 stop bit even check User can set com po...

Page 31: ...on mode station number 255 is free format 1 254 is modbus station number FD8221 Communication format Baud rate data bit stop bit check FD8222 ASC timeout judgment time Unit ms 0 means no timeout waiti...

Page 32: ...l 16384 16927 4000 421F Y0 Y1037 octal 18432 18975 4800 4A1F S0 S1023 20480 21503 5000 53FF M8000 M8511 24576 25087 6000 61FF T0 T618 25600 26218 6400 666A C0 C634 27648 28282 6C00 6E7A Register space...

Page 33: ...ing ENT key press SET key again to cancel the setting and continue modifying the next data register To write the modified value in the register and continue modifying next register After the last regi...

Page 34: ...36 4 2 Build a project XP XMP series product integrated the function of HMI and PLC when editing the HMI screen use HMI software OP20 The interface of OP20 is shown as below About the software...

Page 35: ...the XP XMP is a integrated product of OP and XC the OP will communicate with XC inside the product the communication parameters are defaulted 4 edit the screen After these three steps we can enter sc...

Page 36: ...h the note can not open Click file comm port to select the correct com port 2 download Connect the XP XMP DB9 pins com port and PC serial port using download cable Power on the XP XMP click to start d...

Page 37: ...K thermocouple temperature measurement PID adjustment inside XP3 2PT2AD1DA BD 2 channels PT100 temperature measurement 2 channels analog input 1 channel analog output XP3 2AD2PT BD Item Voltage input...

Page 38: ...t points 2 points Output format NPN collector open transistor output Control precision 0 4 Distinguish ratio 0 1 Integrated precision 0 8 relative max value Convert speed 45ms 2 channels Analog using...

Page 39: ...no insulation among each channel of PLC I O point 0 point As it is operated via data register it is not restricted by master PLC s standard max control points The installation position of BD board on...

Page 40: ...K thermocouple temperature control MA 6PT P 6 channels PT100 temperature control Type Description MA 8X8YR 8 channels digital input 8 channels digital relay output MA 16X 16 channels digital input MA...

Page 41: ...input type Voltage input Current input Analog input range 0 5V 0 10V 0 20mA 4 20mA Maximum input range DC 18V 0 40mA Digital output range 12 bits binary value 0 4095 Resolution 1 4095 12Bit PID output...

Page 42: ...1000 Digital output range 0 4095 12 bits with sign binary Precision 1 Integrated precision 1 Conversion speed 20ms 1 channel Power supply for analog DC24V 10 50mA Installation Use M3 screw or fix on...

Page 43: ...G N D A O XP XMP MA station No 1 MA station No 16 The details and using method please refer to MA Model Manual 5 3 Other extension Besides BD board and MA model XP XMP series product can extend other...