63
Y2
M2
Y3
X2 M1
X3
Y2
T1
3-4. [OR] , [ORI]
Use the OR and ORI instructions for parallel connection of contactors. To connect a block
that contains more than one contactor connected in series to another circuit block in parallel,
use ORB instruction, which will be described later;
OR and ORI start from the instruction step, parallel connect with the LD and LDI
instruction step introduced before. There is no limit for the parallel connect times.
LD
X2
AND
M1
OUT
Y2
LD
Y2
ANI
X3
OUT
M2
AND
T1
OUT
Y3
Mnemonic
Function
Format and Operands
OR
(OR)
Parallel connection
of NO (Normally
Open) contactors
M0
Operand: X,Y,M,HM,SM,S,HS,T,HT,C,HC,Dn.m
ORI
(OR
reverse)
Parallel connection
of NC (Normally
Closed) contactors
M0
Operand: X,Y,M,HM,SM,S,HS,T,HT,C,HC,Dn.m
Program
Mnemonic and Function
Statements
Program