Connecting digital output to an NPN-compatible PLC device input (biased)
Output state
Output switch state
Input state
ON
Sourcing current
Pull up (energized)
OFF
Relaxing
Not energized
Figure 20: connecting digital output to a NPN-compatible PLC device input (biased)
Note:
If using this configuration, take into account that Common Ground connection may be biased by power supply for Digital Input!