xiQ - Technical Manual Version 1.35
19
3.5.
Model Specific Characteristics
3.5.1.
MQ003xG-CM
3.5.1.1.
Sensor and camera parameters
xiQ model
MQ003CG-CM
MQ003MG-CM
Sensor parameter
Brand
CMV300ES-3E7C1WP
CMV300ES-3E7M1WP
Color filter
RGB Bayer mosaic
None
Type
Global shutter, overlap mode
Pixel Resolution (H × V)
[pixel]
648 × 488, usable: 644 x 484 (b/w)
3
/ 640 x 480 (color)
Active area size (H × V)
[mm]
4.8 × 3.6
Sensor diagonal
[mm]
5.9
Optical format
[inch]
1/3
Pixel Size (H × V)
[µm]
7.4 × 7.4
ADC resolution
[bit]
12
FWC
[ke-]
20
Dynamic range
[dB]
60
SNR Max
[dB]
>40 (TBD)
Dark noise
[e-]
20 (RMS)
Dark current
[e-/s]
120 (25°C)
DSNU
[LSB
10
/s]
3
Sensitivity
[V/(Lux s)]
6
Camera parameters
Digitization
[bit]
12
Supported bit resolutions
[bit/pixel]
8, 10, 12
Exposure time (EXP)
54µs to 1sec, in steps of 7.56µs
1
Variable Gain Range (VGA)
[dB]
6
Refresh rate (MRR)
[fps]
>500
Power consumption
typical
[W]
1.5
Peak
2
[W] / [µs]
2.2 / 20
Dimensions/Mass
height
[mm]
26.4
width
[mm]
26.4
depth
[mm]
25.3 (with C/CS Mount module B)
20.3 (without C/CS Mount module B)
mass
[g]
26.4 (with C/CS Mount module B)
22.4 (without C/CS Mount module B)
3.4 (board level camera)
table 3-6, MQ003xG-CM, sensor and camera parameters
Notes:
1)
Defined for max. bandwidth. By decreasing the bandwidth the minimum exposure time and exposure step will
increase. Maximal achievable FPS will decrease.
2)
Short peaks in drained power needed by sensor during pixel area reset
3)
There are 4 dark reference rows available on the sensor (rows 0, 1, 486 and 487) and 2 dark reference
columns (column 0 and 1). Columns 646 and 647 are test columns and do not contain useful image data. This
means that the useable image data area is 644 x 484.