xiQ - Technical Manual Version 1.35
42
3.8.
xiQ Flex cable interface
The flex cable interface is located on the back of the camera and comes with two different options based on the orientation the
cable plugs into the camera. The (FL) version of the camera allows the cable to approach from the bottom of the camera and the
(FV) version has the cable connecting to the camera perpendicular to the sensor surface.
Camera model
Connector
Camera model
Connector
-FL
Molex 502244-1530
-FV
Molex 502231-1500
Table 3-23 Connector part numbers
3.8.1.
Flex Connection Location
figure 3-33 Flex connector location
3.8.2.
Pinning
Pin
Signal
Technical description
1
GND
Ground for power return and for SuperSpeed signal return
2
SSRX-
SuperSpeed receiver dif. pair (accepts reverse polarity)
3
SSRX+
SuperSpeed receiver dif. pair (accepts reverse polarity)
4
GND
Ground for power return and for SuperSpeed signal return
5
SSTX+
SuperSpeed transmitter dif. pair (accepts reverse polarity)
6
SSTX-
SuperSpeed transmitter dif. pair (accepts reverse polarity)
7
GND
Ground for power return and for SuperSpeed signal return
8
D+
USB 2.0 differential pair
9
D-
USB 2.0 differential pair
10
GND
Ground for power return and for SuperSpeed signal return
11
VBUS
+5V Power input
12
VBUS
+5V Power input
13
OUT1
Trigger/sync digital Output (GPO) - Open collector NPN
14
IN/OUT GND
Common pole (IO Ground
15
IN1
Trigger/sync digital Input (GPI) Current limited input
Ground pins
SGND
Shield of FPC cable connected to shield of host controller
table 3-24 Pin list for flex cable
USB 3.0
POWER
IO