xiMU - Technical Manual Version 2.10
63
Multiple cameras interconnection
figure 4-12, connecting multiple MU9 cameras in MASTER-SLAVE (SLAVE on right)
To connect different camera model, please consult respective camera model manual for IO connection. In case of different
voltage levels signal conditioning may be needed.
4.8.2.
Connect Cameras to PC
Connect both cameras to PC.
Note: Be sure that each camera is connected to different USB controller. If a camera is connected to the USB hub/controller with
other devices present (e.g. camera), the acquisition will not be stable. Please use xiCOP (see
) to detect
connection architecture issues.
4.8.3.
Control the Cameras with xiAPI
•
Install the latest version of the XIMEA API Software Package
•
Open the project example xiSample (c:/XIMEA/Examples/xiSample) in Microsoft Visual Studio
•
Replace the file xiSample with the source file from this site:
https://www.ximea.com/support/wiki/standard-
cameras/Connecting_Two_MU9_Cameras_With_Synchronized_Acquisition
For more information about programming please see
xiMU
xiMU
GND
GND
GX1
GX2
GX2 and GX3
set to to exposure active neg
GX1
set as trigger input rising edge
xiMU
GND
GX1
xiMU
GND
GX1
xiMU
GND
GX1
GX3