background image

  

XIEGU  COMMUNICATIONS 

3.1.3  Connection method between XPA125B and other QRP radio 

If you want to start the XPA125B power amplifier and put it into the transmit 
mode, you need to set the PTT port to a low level 

[level≤0.1V]. 

If the PTT output signal of the transceiver is at high level, the high level 
needs to be converted into a low level, and then input to the XPA125B 
[ACC-PTT] port. 

Note: If a voltage of 

3.2V is applied to the PTT port of the XPA125B, the internal 

processor will be permanently damaged! 

Pin 2 of the XPA125 ACC port is the PTT input port 

In order to achieve automatic band switching, the corresponding band voltage 
is needed. XPA125B band control voltage information is as follows. 

BAND 

LEVEL(mV) 

230 
460 
690 
920 

BAND 

LEVEL(mV) 

1380 
1610 
1840 
2070 

BAND 

50.0 MHz 

---- 
---- 
---- 

LEVEL(mV) 

2530 

---- 
---- 
---- 

1.8 MHz 
3.8 MHz 
5.0 MHz 
7.0 MHz 
10.0 MHz 

14.0 MHz 
18.0 MHz 
21.0 MHz 
24.0 MHz 
28.0 MHz 

1150 

2300 

---- 

---- 

3.2 Procedure: 
3.2.1  Using the  power  amplifier  unit  [PA  unit] 

(ATU  unit  is  set  to OFF) 

Press the PA key,so that the state of the amplifier is 

[ON]. 

If  your connected transceiver is an X108G  or X5105, please set 
the output power to 5 W. 
If you are using any other QRP transceiver, please set the output 
power to 1 W. 

Set  your  transceiver  to  CW  mode,  press  the 

CW key  to 

transmit, 

and the XPA125B amplifier will be activated

The output power of the XPA125B can be adjusted by adjusting 
The output power of 

the connected transceiver. 

Summary of Contents for XPA125B

Page 1: ...V 1 00 0 XIEGU 100 W Solid State Linear Power Amplifier XPA125B Instruction Manual Copyright 2010 2018 Xiegu Communications...

Page 2: ...F output power of Do not expose the unit to moisture 100 Watts Auto tuning function Wide frequencyrangeof 0 5 54 MHz Harmonic suppression of 50 dB The maximum output power is automatically constant cu...

Page 3: ...bient temperature 55 Gain 13dB 1dB Spurious suppression 50dB Supply voltage 12 15 V DC Current draw maximum output Standby 700 mA Max Transmit 30A Max 1 2 ATU Tuning frequency range 1 8 30 MHz 50 54 M...

Page 4: ...or 2 seconds XPA125B will turn on ATU function key Via this button you can access the automatic antenna tuning function BAND selection key Using this button you can select between manual band switchin...

Page 5: ...tective plate 2 2 Rear panel layout DC IN Power supply socket The XPA125B requires a 12 15 V DC supply 7 ANT Connector The ANT socket is connected to the antenna the connector model is SL16 K 8 FUSE H...

Page 6: ...erface is for XPA125B firmware updates and connection to a PC 2 3 Display interface layout Input SWR value Displays the SWR value of the XPA125B input Operating voltage Displays the value of DC voltag...

Page 7: ...ng band status Displays the current working band and whether automatic or manual mode is selected The figure above shows the 6 meter band 9 Output power value Displays the output power being delivered...

Page 8: ...CC ports of the two units Both connectors are the same so either end of the cable can be connected to either socket Use suitable RF coaxial cable to connect the X108G ANT port to the XPA125B TRX port...

Page 9: ...e corresponding band voltage is needed XPA125B band control voltage information is as follows BAND LEVEL mV 230 460 690 920 BAND LEVEL mV 1380 1610 1840 2070 BAND 50 0 MHz LEVEL mV 2530 1 8 MHz 3 8 MH...

Page 10: ...band Manual switching of frequency bands follows this order 160m 80m 60m 40m 30m 20m 17m 15m 12m 10m 6m 3 2 3 Using the automatic antenna tuner unit ATU PA unit is set to OFF state Press the ATU butto...

Page 11: ...PA unit and ATU unit The ATU unit and PA unit of XPA125B can be used independently of each other You can therefore use the XPA125B as either an automatic antenna tuner or a separate power amplifier Yo...

Page 12: ...S Warning When the XPA125B current draw is too high more than 25A or a short circuit occurs the fuse on the rear panel may blow The unit will then no longer turn on Please check the status of the fuse...

Page 13: ...the shipping both ways After two weeks XieGu will pay only for return shipping If the product is not covered under warranty the customer pays for shipping both ways plus the cost of the repair 2 Warra...

Page 14: ...s are covered by the warranty A Damage caused by improper use by the user B Damage caused by an accident C Damage due to incorrect testing maintenance debugging or other changes D Damage is not caused...

Page 15: ...XIEGU COMMUNICATIONS www cqxiegu com...